In this tutorial, we will focus on FANUC CNC Integration with CNC gateway. We hope this proves helpful.
In the previous lessons, we covered :
How the EG8200 Mini CNC Gateway interfaces with Siemens CNC systems
How to Integrate the CNC Gateway with Mitsubishi CNC
How to Integrate the CNC Gateway with New Generation CNC
How to Integrate the CNC Gateway with HAAS CNC
How the EG series CNC gateway interfaces with Maritx CNC
This lesson will provide a detailed explanation for FANUC CNC systems.
Compatible CNC: Fanuc Series 0iD/0iF/30i/31i/32i/35i
1. Hardware Connection
The Fanuc CNC protocol uses Ethernet communication. Therefore, only ensure the gateway’s LAN port IP and the CNC’s IP are within the same subnet (Note: In special cases, they may be on different subnets, requiring routing configuration—consult technical support for details). IP addresses are assigned as follows in this example:
EG8200Mini-CNC gateway |
FANUC CNC |
|
IP-adres |
192.168.110.88 |
192.168.110.108 |
2. CNC Communication Parameters
Provided by CNC engineers.
The CNC network port parameters are:
IP: 192.168.110.108
Port: 8193
FANUC CNC IP Configuration Panel:
FANUC Port Configuration Interface:
3. Gateway Settings
3.1. CNC Connection Settings
Drag a Fanuc node from the CNC panel on the left. Double-click to open the settings page and configure as follows based on the PLC parameters:
Address: 192.168.8.16
Port: 8193
Connection Timeout: 5000
Heartbeat Interval: 60000
Data Timeout: 2000
Data Interval: 1000 (Read Cycle)
Cycle Wait: 1000 (Data Point Read Interval)
3.2. Data Point Settings
Check the required data points.
3.3. Testing
Click Deploy and observe a data point being printed every few seconds. Verify the received data points to confirm successful communication!
For the data point reference table, please refer to:
This is a Yueque content card. Click the link to view: https://iotrouter.yuque.com/zn3vdn/eg8000/om7gm3hef68gt7fb