In this tutorial, we will focus on FANUC CNC Integration with CNC gateway. We hope this proves helpful.
В предыдущих уроках мы рассмотрели :
Как мини-шлюз ЧПУ EG8200 взаимодействует с системами ЧПУ Siemens
Как интегрировать шлюз ЧПУ с системой ЧПУ Mitsubishi
Как интегрировать шлюз ЧПУ с ЧПУ нового поколения
How to Integrate the CNC Gateway with HAAS CNC
How the EG series CNC gateway interfaces with Maritx CNC
This lesson will provide a detailed explanation for FANUC CNC systems.
Compatible CNC: Fanuc Series 0iD/0iF/30i/31i/32i/35i
1. Подключение оборудования
The Fanuc CNC protocol uses Ethernet communication. Therefore, only ensure the gateway’s LAN port IP and the CNC’s IP are within the same subnet (Note: In special cases, they may be on different subnets, requiring routing configuration—consult technical support for details). IP addresses are assigned as follows in this example:
|
EG8200Мини-шлюз ЧПУ |
FANUC CNC |
|
| IP-адрес |
192.168.110.88 |
192.168.110.108 |


2. CNC Communication Parameters
Provided by CNC engineers.
The CNC network port parameters are:
IP: 192.168.110.108
Порт: 8193
FANUC CNC IP Configuration Panel:

FANUC Port Configuration Interface:

3. Настройки шлюза
3.1. Настройки подключения ЧПУ
Drag a Fanuc node from the CNC panel on the left. Double-click to open the settings page and configure as follows based on the PLC parameters:
Адрес: 192.168.8.16
Порт: 8193
Таймаут соединения: 5000
Интервал сердцебиения: 60000
Таймаут данных: 2000
Интервал данных: 1000 (Read Cycle)
Цикл ожидания: 1000 (Data Point Read Interval)

3.2. Data Point Settings
Check the required data points.

3.3. Тестирование
Нажмите кнопку Развернуть и наблюдайте, как каждые несколько секунд печатается точка данных. Проверьте полученные точки данных, чтобы подтвердить успешную связь!
Справочную таблицу точек данных см:
Это карта содержимого Yueque. Нажмите на ссылку для просмотра: https://iotrouter.yuque.com/zn3vdn/eg8000/om7gm3hef68gt7fb