EG8200Mini-104: Modbus To IEC 104 Gateway For Substation And SCADA Systems - IOTROUTER
Animación Hover

EG8200Mini-104: Modbus to IEC 104 Gateway for Substation and SCADA Systems

Reliable IEC 104 Protocol Converter for Power Systems

EG8200Mini-104 connects Modbus devices to IEC 104 SCADA systems with millisecond-level data acquisition for power and substation applications.

Video Video





Industry Protocols
CJ188/DLT645/HJ212/1EC104/Modbus/OPC UA/BACnet
Network Protocols
MQTT/ HTTP /TCP/ UDP /WEBSOCKET

INTERFACE

2*RS485, 1*RS232, 1*WAN, 1*LAN
COMMUNICATION
LTE 4G, RJ45, WiFi

Categorías: , Buy on Alibaba

Descripción

EG8200Mini-104 is an IEC 104 Gateway (IEC 60870-5-104 gateway ) designed for power automation and substation communication. It enables seamless conversion of Modbus RTU/TCP and PLC data into IEC 104 for integration with SCADA and dispatch systems.

It supports flexible master-slave configuration for bidirectional data exchange, as well as multi-device networking to interconnect multiple IEC 104 devices within a LAN. With support for multiple industrial protocols, remote management, and stable network connectivity, it ensures reliable data acquisition and transmission in energy and utility environments.

Key Features

iiotGateway_keyfeatures_01

IEC 104 Server/Client

Standard Server/Client modes for stable SCADA

iiotGateway_keyfeatures_02

Low-Code Development

Visual programming with built-in Node-RED

iiotGateway_keyfeatures_03

Remote Virtual LAN

Virtual LAN for remote PLC access and program upload/download

iiotGateway_keyfeatures_04

Multi-Protocol

Seamless communication across industrial protocols

iiotGateway_keyfeatures_05

Edge Intelligence

Local data analysis and logic execution at the edge

iiotGateway_keyfeatures_06

Gestión remota

Remote configuration, debugging, and program updates

iiotGateway_keyfeatures_07

Reliable Connectivity

4G / Ethernet / Wi-Fi with auto failover

iiotGateway_keyfeatures_08

Industrial-Grade

Operates from −40°C to 85°C with 9–36V wide voltage input

* Ayuda OEM/ODM, contact customer service for details.


Pasarela de borde EG8200Mini-104 Modbus RTU TCP a IEC104 Pasarela de borde EG8200Mini-104 Modbus RTU TCP a IEC104


EG Series Products

All gateways in the EG series share a highly consistent operating method. Differences between models are mainly reflected in hardware interfaces, and the corresponding variations are limited to the presence or absence of certain functional nodes.

EG Series8200 Pro82008200 Mini8200 Lite82082000
Key FeatureAlto rendimientoMulti-interfaceStandard VersionDIN-rail VersionCNC VersionIEC104 VersionLow Cost8 Serial PortsPasarela LoRa
ProcessorOcta-core A55 @1.8GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzA7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHz
Memoria2GB512MB512MB512MB512MB512MB256MB512MB512MB
eMMC16 GB4GB4GB4GB4GB4GB4GB4GB4GB
SD CardMax 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)×Max 128GB (optional)Max 128GB (optional)
4G×√ (optional)√ (optional)
5G√ (optional)××××××××
HDMI××××××××
Puertos Ethernet1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN/LAN1×WAN/LAN1×WAN/LAN
LoRa××××××××
Wi-FiDual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6×××
GPS××××××××
USB2×USB 2.01×USB 2.0×××××××
RTC×
RS485322222281
RS232111111×××
CAN×2×××××××
DO22×××××8×
DI22×××××××
AO2××××××××
AI2××××××××
Tensión de funcionamiento9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V
Corriente de funcionamiento500mA@12V280mA/12V150 mA/12 V150 mA/12 V150 mA/12 V150 mA/12 V60mA/12V170mA/12V180mA/12V
CertificaciónCECECECECECECECECE
Temperatura de funcionamiento-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-20 ~ 85°C-40 ~ 85°C-40 ~ 85°C
Remote O&M
Gestión remota
Remote Upgrade
Virtual Network Interface
Virtual Serial Port
Local Database×
Visual Programming
PLC Protocol×××
CNC Protocol××××××××
IEC 60870-5-104××××××××
Web Configuration××××××××
Industry ProtocolsCJ188/DLT645/HJ212/Modbus/OPC UA*/BACnet*/etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical
Network ProtocolsMQTT / HTTP / TCP / UDP / WebSocket / Alibaba Cloud IoT Platform / OneNET / etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical

Quick Access to EG Series Products →


Main Functions

EG8200Mini-104 Modbus to IEC 104 Gateway01

Wide PLC Compatibility

– Millisecond-Level Data Acquisition – 

Supports communication with major PLC brands, including Siemens, Mitsubishi (MELSEC), Omron, Allen-Bradley, Beckhoff, Inovance, Keyence, Panasonic, Delta, and others, enabling rapid PLC data acquisition for edge applications. For a detailed list of supported PLC protocol models, please contact customer service.

Multi-Protocol Support

– Third-Party Platform Integration –

Supports standard industrial protocols, including Modbus, MQTT, OPC UA/DA, HJ212, and IEC 60870-5-104, enabling seamless integration with SCADA systems, cloud platforms, and other third-party applications. For non-standard protocols, custom parsing and logic can be implemented using JavaScript (JS).

EG8200Mini-104 Modbus to IEC 104 Gateway02
EG8200Mini-104 Modbus to IEC 104 Gateway05

Gestión remota

The EG8200 series remote management software enables remote configuration, debugging, diagnostics, and program updates for on-site devices.

Remote Virtual LAN

– PLC Remote Upload & Download –

With Virtual Ethernet and Virtual Serial Port, engineers can remotely access PLCs, HMIs, and serial devices for programming, maintenance, and debugging as if they were on the same local network.

EG8200Mini-104 Modbus to IEC 104 Gateway07
EG8200Mini-104 Modbus to IEC 104 Gateway08

Drag & Drop Programming

– Low-code visual programming –

Using Node-RED visual programming, the EG8200Mini-104 gateway allows users to build automation workflows through drag-and-drop configuration. It supports integration with sensors and third-party platforms via protocols such as MQTT and JSON.



PREGUNTAS FRECUENTES

Q1: What network options does the EG8200Mini-104 edge IEC 104 Gateway support? How can I use it in a substation without Ethernet?

A: EG8200Mini-104 IEC 104 Gateway offers very flexible networking options, fitting a variety of industrial site scenarios:

    • Wired (RJ45): Connect via the Gigabit WAN port or 100Mbps LAN port to your local network.

    • Wi-Fi: Supports dual-band Wi-Fi (2.4GHz & 5GHz) as a client to connect to existing wireless networks.

    • Cellular (4G LTE): Built-in 4G Cat.1 module—just insert a SIM card, and your gateway can send data over the mobile network.

So even in older substations with no network cables, you can still use 4G to reliably send data back to the control center.

Q2: How do I use the EG8200Mini-104 IEC 104 Gateway to read substation digital and analog data? Is it complicated?

A: Configuration is straightforward using the visual Nodo-RED tool—no coding required. Here’s the core workflow:

1. Network setup: Ensure the gateway is on the same network as your substation devices (e.g., protection relays). You can adjust the LAN IP via the management interface.

2. Add nodes: In Node-RED, drag an IEC104 Client node from the left palette into your workflow.

3. Configure connections and points:

      • In the node settings, enter the remote 104 slave’s IP address and port (default is 2404).

      • Digital inputs (DI/status points): Go to the “Digital” tab, add the points using the slave’s point addresses (like 1, 2), and assign names.

      • Analog inputs (AI/measurements): Go to the “Analog” tab, add the points with the corresponding addresses (like 16385, 16386) and names.

    1. 4. Deploy & verify: Once deployed, the gateway will automatically read data at the configured intervals. You can monitor real-time values in the debug panel.

Product Size and Interfaces

EG8200Mini-104 Modbus to IEC 104 Gateway09


Packing List

EG8200Mini-104 Modbus to IEC 104 Gateway10


pasarela industrial edge

Ficha de datos

HardwareCPU2*Cortex-A7@1.2GHz
Memoria512M
EMMC4G (MLC)
Tarjeta SDHasta 128 G (influxdb preinstalado)
RTCReloj en tiempo real
InalámbricoLTE Cat1
WAN1*10M/100M/1000M Autoadaptable
LAN1*10M/100M Self-Adaptive
WiFiAP+Estación
RS4852* RS485
RS2321* RS232
LEDPersonalizable
Parámetros eléctricosTensión de funcionamiento9~36V
Corriente de funcionamiento150 mA/12 V
Adapter12V/2A
Protección eléctricaAntiestático, antisobretensión, antirretorno
CertificaciónCE/ROHS/FCC
Parámetros medioambientalesTemperatura de funcionamiento-40~85℃
Temperatura de almacenamiento-40~85℃
Humedad de funcionamiento0-95%RH(No Condensation)
Método de refrigeraciónDisipador de calor/Silicona disipadora
Parámetros mecánicosTalla115*90*35mm/125*95*32mm
Peso<1kg
MaterialAleación de zinc
Parámetros de softwareOperacionesSoporta configuración/actualización/gestión remota
VPNAdmite penetración en intranet/carga y descarga remotas de PLC/puerto serie virtual
Computación de bordeAdmite programación visual, desarrollo de código cero, programación de arrastrar y soltar, desarrollo secundario, sin compilación
Almacenamiento de datosAdmite colas de caché/lectura y escritura de archivos/transferencia desconectada/ influxdb
Acuerdo industrialCompatible con múltiples protocolos industriales
Protocolo de redMQTT/HTTP/TCP/UDP

Protocolos PLC

Protocolos PLC de la pasarela Edge Computing serie EG8000

La pasarela se clasifica según la estructura jerárquica de marca->protocolo->modelo, y en cada categoría se seleccionan modelos de PLC representativos para las pruebas. El resto de modelos admitidos proceden de los documentos oficiales.
Nota: La pasarela es compatible con el protocolo estándar MOBUDS RTU/TCP, que es compatible con todos los PLC de uso general. (Por ejemplo, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

MarcaProtocoloInterfazModelo PLC
SIEMENSConsejos:Siemens en la venta de la serie todos apoyan la comunicación de protocolo S7, se recomienda utilizar la comunicación de protocolo S7.
S7EthernetS7-S200smart, Serie S7-S200, Serie S7-S300, Serie S7-S400, Serie S7-S1200, Serie S7-S1500
PPIPuerto serieSerie S7-200
MELSECConsejos:Mitsubishi utiliza principalmente el protocolo MC para la comunicación, Serie FX5, Serie FX3, Serie Q, etc. están probados.
EtherNet/IPEthernetSerie FX5-ENET/IP, Serie RJ71EIP91, Serie QJ71EIP71
MC-1E/MC-3EEthernetSerie FX5, Serie RJ71EN71, Serie RnENCPU, Serie LJ71E71, Serie QJ71E71, Serie QnUCPU, Serie FX3
MODBUS TCPEthernetSerie FX5, Serie RJ71EN71, Serie RnENCPU, Serie LJ71E71, Serie QJ71E71
MC-3CPuerto serieSerie FX5, Serie RJ71C24, Serie LJ71C24, Serie QJ71C24
MODBUS RTUPuerto serieSerie FX5, Serie RJ71C24, Serie LJ71C24, Serie QJ71C24, Serie FX3
FxLinksPuerto serieSerie FX3, Serie FX2, Serie FX1, Serie FX0
FxSerialPuerto serieSerie FX3, Serie FX2, Serie FX1, Serie FX0
OMRONConsejos:Omron utiliza principalmente el protocolo Fins para la comunicación.
EtherNet/IPEthernetSerie NX7, Serie NX1, Serie NX1P, Serie NJ, CJ1W-EIP21
AletasEthernetSerie CP, Serie CS, Serie CJ, Serie CV
HostLinkPuerto serieSerie CP, Serie CS, Serie CJ, Serie CV, Serie C
LSisConsejos:LS utiliza principalmente el protocolo FEnet/Cnet para la comunicación.
XGB FEnetEthernetSerie XGB (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetSerie XGT (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetPuerto serieSerie XGB (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetPuerto serieSerie XGT (XGL-CH2A, XGL-C21A, XGL-C41A)

MarcaProtocoloInterfazModelo PLC
AllenBrandlyConsejos:Rockwell utiliza principalmente el protocolo CIP, DF1 para la comunicación.
EtherNet/IPEthernetSerie ControlLogix, Serie CompactLogix, Serie Micro800 (820, 850, 870)
DF1Puerto serieSerie ControlLogix, Serie CompactLogix (módulo 5069-SERIAL) , Serie Micro800 (820, 830, 850, 870)
Serie SLC (500, 5/03, 5/04, 5/05) , Serie Micro-Logix (1000, 1100, 1200, 1500)
BeckhoffConsejos:Beckhoff utiliza principalmente el protocolo ADS para la comunicación.
ADSEthernetSerie CX, TwinCAT2, TwinCAT3
InovanceConsejos:Inovance adopta principalmente el protocolo MODBUS para la comunicación.
MODBUS TCPEthernetSerie AC, Serie AM, Serie H5U, Serie H3U
MODBUS RTUPuerto serieSerie AC, Serie AM, Serie H5U, Serie H3U, Serie H1U
KeyenceConsejos:Keyence utiliza principalmente el protocolo KV para la comunicación.
MC-3EEthernetSerie KV-8000, Serie KV-7000, Serie KV-5500, Serie KV-5000
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A y otras unidades Ethernet
KVEthernet
KVPuerto serieKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicConsejos:Panasonic utiliza principalmente el protocolo Mewtocol para la comunicación.
MC-3EEthernetSerie FP7, Serie FP0H, Serie FP-XH
MewtocoloEthernetSerie FP7, Serie FP0H, Serie FP-XH
MewtocoloPuerto serieSerie FP7, Serie FP0H, Serie FP-XH, Serie FP-X0, Serie FP0R
DeltaConsejos:Delta utiliza principalmente el protocolo MODBUS para la comunicación.
MODBUS TCPEthernetSerie AH, Serie AS, Serie AX-3, Serie DVP (Ethernet integrada)
MODBUS RTUPuerto serieSerie AH, Serie AS, Serie AX-3, Serie DVP
XinJEConsejos:XinJE utiliza principalmente el protocolo MODBUS para la comunicación.
MODBUS TCPEthernetSerie CCSD, Serie XA, Serie XS, Serie XG, Serie XL
MODBUS RTUPuerto serieSerie CCSD, Serie XA, Serie XS, Serie XG, Serie XL, Serie XC, Serie XD
MegMeetConsejos:MegMeet utiliza principalmente el protocolo MODBUS para la comunicación.
MODBUS TCPEthernetSerie MC5100, Serie MC280, Serie MC200, Serie MC100, Serie MC80
MODBUS RTUPuerto serieSerie MC5100, Serie MC280, Serie MC200, Serie MC100, Serie MC80
YaskawaConsejos:Yaskawa utiliza principalmente el protocolo MEMOBUS para la comunicación (compatible con S7) .
MemobusEthernetSerie GL120/130, Serie GL60, Serie MP3000, Serie MP2300, Serie Z1000
FatekConsejos:Fatek utiliza principalmente el protocolo Fatek para la comunicación.
FatekPuerto serieSerie FBs
VigorConsejos:Vigor utiliza principalmente el protocolo privado VS para la comunicación.
VSPuerto serieSerie VS
FujiConsejos:Fuji utiliza principalmente el protocolo SPH/SPB para las comunicaciones.
SPHEthernetSerie SPH
SPBPuerto serieSerie SPB

Bandas 4G

*You may contact customer service to select the corresponding module for replacement.
 
Módulo TyleBandas de frecuencia
EC800K-CNLTE FDD: B1/B3/B5/B8
LTE TDD: B34/B38/B39/B40/B41
EG800K-EULTE FDD: B1/B3/B5/B7/B8/B20/B28
EG800K-LALTE FDD: B2/B3/B4/B5/B7/B8/B28/B66

Descargar

Apply For Product Samples