Procurar

EV8010 10.1″ All-in-One Industrial Panel PC & HMI Edge Gateway

Integrated HMI & IoT Edge Gateway

An industrial IoT computer with a touch screen, used for automation, edge computing, and remote monitoring.




Protocolos do sector
CJ188 / DLT645 / HJ212 / Modbus / OPC UA / BACnet, etc
Protocolos de Rede
MQTT / HTTP / TCP / UDP / WEBSOCKET
INTERFACE
2*RS485, 1*RS232, 1*USB 2.0, 1*WAN(GE), 1*LAN(FE)
MEMORY & STORAGE
2G RAM + 16G eMMC
COMMUNICATION
4G

Categorias: , Comprar no Alibaba

Descrição

The EV8010 is a rugged industrial panel PC & HMI edge gateway that integrates a multi-protocol data acquisition gateway with a 10.1″ HD touch display. The screen supports millisecond-fast response times and can recognize multiple touch gestures. It provides an all-in-one solution for visualization and edge computing.

EV8010 industrial computer features an 8-core high-performance processor with strong graphics capabilities. Its main frequency reaches up to 1.8 GHz, ensuring smooth, non-lagging operation for 24/7, all-weather use.

It supports multi-protocol data acquisition, protocol conversion, and edge processing, along with Node-RED-based programming and remote deployment. Web-based configuration via FUXA enables flexible and intuitive operation across various IoT applications.


Key Features

iiotGateway_keyfeatures_01

Industrial-Grade

-20~70°C operation, 9–36V input, surge & ESD protection

iiotGateway_keyfeatures_02

Zero-Code Logic

Visual configuration with built-in Node-RED

iiotGateway_keyfeatures_03

Integrated HMI + Gateway

Data acquisition, protocol conversion, and visualization in one device

iiotGateway_keyfeatures_04

Multi-Protocol PLC

Siemens, Mitsubishi, Omron → MQTT / HTTP

iiotGateway_keyfeatures_05

Alarm & Data Management

Supports alarm events, historical data storage, and visualization

iiotGateway_keyfeatures_06

Web-Based HMI

Access and control HMI screens via browser, anytime, anywhere

iiotGateway_keyfeatures_07

Multi-Screen Display

One project accessible across multiple devices simultaneously

iiotGateway_keyfeatures_08

FUXA Visualization

Direct display of dashboards or SCADA screens

* Apoio OEM/ODM, contact customer service for details.

Remote PLC management via EV8010 industrial computer


Important Attributes

Parâmetros de hardwareDisplay Screen10.1" 16:9 TFT LCD
Viewing Angle85'/85'/85'/85' (T/B/L/R)
Number Of Pixels1280(H)×800(V)
Display Colors16.7M
Brightness400 cd/m²
BacklitLED
LED Lifetime> 50000h
Touch Screen10 Point Capacitive
CPUARM Cortex-A55@1.8GHz
RAMLPDDR4 2GB, 32bits
Armazenamento16GB eMMC
RTCBuilt-in Real-time Clock
Ethernet1 * WAN ( GE ) / 1 * LAN ( FE )
USB1 * USB2.0
Porta de série1 * RS232 / 2 * RS485
4G Full NetcomOptional
Software parametersSistema OperacionalLinux
Programação VisualApoio
Configuração via WEBApoio
Parâmetros eléctricosPotência nominal<8W
Fonte de alimentaçãoDC9~36V
Proteção de energiaAnti-static, Anti-surge, Anti-reverse Connection
Parâmetros ambientaisTemperatura de funcionamento-20~70℃
Temperatura de armazenamento-30~70℃
Humidade ambiental10~90%RH (Non-condensing)
Dissipação de calorPassive Heat Dissipation
Parâmetros mecânicosInstalaçãoEmbedded Installation
Shell MaterialDip Zinc Alloys
Overall Size300mm×203mm×31.4mm
Suggested Hole Size282.5mm×182.5mm

Main Functions

Multi-protocol PLC support Siemens Mitsubishi Omron

Massive PLC Protocols

Millisecond Acquisition – 

The EV8010 industrial panel PC supports seamless integration with mainstream PLC brands, including Siemens, Mitsubishi, Omron, LS, Allen-Bradley, Beckhoff, Inovance, Keyence, Panasonic, Delta, XinJE, MegMeet, Yaskawa, Fatek, Vigor, Fuji, and more.
For the detailed list of supported PLC models and protocols, please refer to the protocol documentation.

Multiple Industry Protocols

– Flexible Protocol Integration –

The EV8010 industrial panel PC acts as a flexible bridge for different industrial systems. It supports common industrial and IoT protocols such as Modbus, MQTT, OPC UA/DA, HJ212, and IEC104, enabling easy integration with third-party platforms.
For non-standard or proprietary protocols. EV8010 allows custom data parsing and logic configuration through JavaScript (JS), providing adaptable protocol handling for complex field applications.

Multiple Industry Protocols_EV8010 Industrial panel PC
Web-based HMI access via FUXA

Web-Based Configuration with FUXA

Using FUXA, effortlessly build highly personalized data visualization dashboards with intuitive drag-and-drop. Users can access the interface via a browser without installing additional software or plug-ins.


Multi-screen Display

– Operate anytime, anywhere –

Thanks to the advantages of web display, the EV8010 industrial computer supports multiple devices to share the screen and supports off-site remote operation.

3 6 11zon
Node-RED visual programming for IoT edge computing

Drag & Drop Programming

– Low-code visual programming – 

EV series products are based on EG series gateway functions, including PLC remote upload and download, various industry protocols, visualization programming, remote operation and maintenance, and so on.


Application Scenarios of the EV8010 All-In-One HMI Gateway

1. Space-Constrained Control Cabinets or Simplified Hardware Architectures

In real-world deployments, separate gateway and HMI devices not only occupy more cabinet space but also increase the complexity of wiring and communication configurations. During commissioning and maintenance, multi-device architectures often require additional troubleshooting due to connection or protocol issues.

The EV8010 industrial panel PC integrates data acquisition and local visualization into a single device. By reducing the number of devices and interconnections, it simplifies system architecture, while also helping to lower hardware investment and long-term maintenance costs.

Typical applications: Power distribution cabinets, compact control cabinets, equipment integration projects, system retrofit projects.

Traditional Solution VS EV8010

Item Traditional Solution

(Gateway + HMI, Two Devices)

Integrated Solution

(Single Device – EV8010)

System structure Separate gateway and HMI devices One integrated device
Configuration Separate setup and integration for each device Unified configuration environment
Development workflow Data processing and HMI interface were developed independently Data, logic, and visualization integrated in one workflow
Communication Multi-device communication required Internal communication within a single system
Debugging complexity Higher, due to cross-device issues Lower, fewer failure points
Maintenance More components to manage and troubleshoot Simplified maintenance with fewer system elements

 

2. All-in-One Integration: Accelerating Delivery for Time-Critical Projects

Under tight project deadlines, the EV8010 consolidates data acquisition, logic control, HMI visualization, and cloud connectivity into a single device. By eliminating the need for constant debugging across multiple software platforms, it significantly reduces integration complexity.

  • End-to-End Workflow: Seamlessly covers everything from acquisition and processing to visualization, control, and cloud upload.

  • High-Efficiency Low-Code Development: Leverage Node-RED and FUXA drag-and-drop tools to reduce programming and debugging cycles by over 50%.

  • Lower Maintenance Costs: Simplifies architecture by removing multi-device networking, reducing potential points of failure, and ensuring on-time delivery.

Typical Applications: Production lines, OEM machinery, and rapid-delivery custom projects.

3. Flexible Access & Remote Collaboration: Breaking the Limits of Local HMI

Traditional HMIs are often tethered to physical screens, making remote monitoring and multi-user collaboration complex and costly. The EV8010 features a Web-based HMI, enabling seamless operation across PCs, tablets, and mobile devices.

  • Unified Access: One interface for both local and remote users, eliminating the need for additional remote access tools.

  • Edge Reliability: Local data processing and logic control ensure the system remains fully operational even during network outages.

  • Enhanced Collaboration: Enables engineers and managers to monitor and maintain systems from anywhere, improving response speed.

Typical Applications: Remote maintenance, cross-regional deployments, and multi-role collaborative management.

The Core Advantage

The EV8010 industrial panel PC is engineered for projects that demand leaner architecture and rapid deployment. By consolidating DAQ, protocol conversion, logic control, and HMI into a single edge node, it enables engineers to develop and manage systems within one unified environment.

  • Eliminate Integration Friction: Reduce inter-device dependencies and communication overhead.

  • Enhanced Controllability: Centralized development ensures higher reliability and on-time project milestones.

  • Lower Maintenance TCO: A simplified architecture means fewer points of failure and reduced long-term service costs.


FAQ

Q1. What level of programming knowledge is required for the EV8010?

A1: The EV8010 industrial panel PC is designed for low-code deployment, eliminating the need for complex manual coding.

    • Logic over Scripting: If you understand basic industrial automation concepts (such as IP addressing, registers, and I/O mapping), you can easily configure the device.

    • Web-Based Configuration: Protocol matching and network settings are handled via an intuitive browser interface—no specialized IDE required.

    • Visual HMI Design: The VISION software features a drag-and-drop editor. Instead of coding graphics, you simply link UI widgets to your data tags.

The Bottom Line: While foundational knowledge of automation is necessary, the EV8010 removes the high barrier of traditional software development, enabling much faster deployment.

Q2. Which PLCs and devices are compatible with the EV8010 industrial panel PC?

A2: The device supports over 90% of mainstream industrial controllers on the market.

  • PLC Compatibility: Includes Siemens, Mitsubishi, Omron, Rockwell Automation, Inovance, Delta, and Xinjie.

  • Physical Interfaces: Equipped with 2x Gigabit Ethernet ports, 1x RS232, and 2x RS485. Any device with Ethernet or Serial output is generally plug-and-play.

  • Analog Sensors: Integration of 4-20mA or 0-10V sensors is easily achieved via standard analog-to-digital converters.

If you are unsure about a specific model, please provide your equipment specifications, and our team will verify compatibility for you.


Dimensions And Interfaces

EV8010 industrial PC interfaces showing RS485 RS232 and Ethernet ports


Packing List

5 8 11zon


Product Installation

EV8010 industrial panel PC- Product Installation

Step 1.

Before installation, it is necessary to open the corresponding installation hole slightly larger than the equipment.

Step 2.

Place the equipment in the reserved installation holes.

Step 3.

There are two square holes on both sides of the equipment, and one end of the square hole is fastened with a buckle during installation; The screws of the buckle are attached to the top of the cabinet, tighten the screws, and the other three parts are the same to complete the installation.

Protocolos PLC

Protocolos PLC das Gateways de Computação de Borda das Séries EV e EG8000

The gateway is categorized according to the hierarchical structure of brand->protocol->model, and representative PLC models are selected for testing in each category. The rest of the supported models are from the official documents. Note: The gateway supports the standard Modbus RTU/TCP protocol, which is supported by all mainstream PLCs. (For example, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

MarcaProtocoloInterfaceModelo PLC
SIEMENSDicas:A Siemens, na venda das séries, suporta a comunicação através do protocolo S7, pelo que se recomenda a utilização do protocolo de comunicação S7.
S7EthernetS7-S200smart, Série S7-S200, Série S7-S300, Série S7-S400, Série S7-S1200, Série S7-S1500
PPIPorta sérieSérie S7-200
MELSECDicas:A Mitsubishi utiliza principalmente o protocolo MC para a comunicação, a série FX5, a série FX3, a série Q, etc. são testadas.
EtherNet/IPEthernetSérie FX5-ENET/IP, Série RJ71EIP91, Série QJ71EIP71
MC-1E/MC-3EEthernetSérie FX5, Série RJ71EN71, Série RnENCPU, Série LJ71E71, Série QJ71E71, Série QnUCPU, Série FX3
MODBUS TCPEthernetSérie FX5, Série RJ71EN71, Série RnENCPU, Série LJ71E71, Série QJ71E71
MC-3CPorta sérieSérie FX5, Série RJ71C24, Série LJ71C24, Série QJ71C24
MODBUS RTUPorta sérieSérie FX5, série RJ71C24, série LJ71C24, série QJ71C24, série FX3
FxLinksPorta sérieSérie FX3, Série FX2, Série FX1, Série FX0
FxSerialPorta sérieSérie FX3, Série FX2, Série FX1, Série FX0
OMRONDicas:A Omron utiliza principalmente o protocolo Fins para a comunicação.
EtherNet/IPEthernetSérie NX7, Série NX1, Série NX1P, Série NJ, CJ1W-EIP21
BarbatanasEthernetSérie CP, Série CS, Série CJ, Série CV
HostLinkPorta sérieSérie CP, Série CS, Série CJ, Série CV, Série C
LSisDicas:O LS utiliza principalmente o protocolo FEnet/Cnet para a comunicação.
XGB FEnetEthernetSérie XGB (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetSérie XGT (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetPorta sérieSérie XGB (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetPorta sérieSérie XGT (XGL-CH2A, XGL-C21A, XGL-C41A)
MarcaProtocoloInterfaceModelo PLC
Allen-BrandlyDicas:A Rockwell utiliza principalmente o protocolo CIP, DF1 para a comunicação.
EtherNet/IPEthernetSérie ControlLogix, Série CompactLogix, Série Micro800 (820, 850, 870)
DF1Porta sérieSérie ControlLogix, Série CompactLogix (módulo 5069-SERIAL) , Série Micro800 (820, 830, 850, 870)
Série SLC (500, 5/03, 5/04, 5/05) , Série Micro-Logix (1000, 1100, 1200, 1500)
BeckhoffDicas:A Beckhoff utiliza principalmente o protocolo ADS para a comunicação.
ADSEthernetSérie CX, TwinCAT2, TwinCAT3
InovanceDicas:Inovance adopta principalmente o protocolo MODBUS para a comunicação.
MODBUS TCPEthernetSérie AC, Série AM, Série H5U, Série H3U
MODBUS RTUPorta sérieSérie AC, Série AM, Série H5U, Série H3U, Série H1U
KeyenceDicas:A Keyence utiliza principalmente o protocolo KV para a comunicação.
MC-3EEthernetSérie KV-8000, Série KV-7000, Série KV-5500, Série KV-5000
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A e outras unidades Ethernet
KVEthernet
KVPorta sérieKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicDicas:A Panasonic utiliza principalmente o protocolo Mewtocol para a comunicação.
MC-3EEthernetSérie FP7, Série FP0H, Série FP-XH
MewtocolEthernetSérie FP7, Série FP0H, Série FP-XH
MewtocolPorta sérieSérie FP7, Série FP0H, Série FP-XH, Série FP-X0, Série FP0R
DeltaDicas:A Delta utiliza principalmente o protocolo MODBUS para a comunicação.
MODBUS TCPEthernetSérie AH, Série AS, Série AX-3, Série DVP (Ethernet incorporada)
MODBUS RTUPorta sérieSérie AH, Série AS, Série AX-3, Série DVP
XinJEDicas:O XinJE utiliza principalmente o protocolo MODBUS para comunicação.
MODBUS TCPEthernetSérie CCSD, Série XA, Série XS, Série XG, Série XL
MODBUS RTUPorta sérieSérie CCSD, Série XA, Série XS, Série XG, Série XL, Série XC, Série XD
MegMeetDicas:O MegMeet utiliza principalmente o protocolo MODBUS para comunicação.
MODBUS TCPEthernetSérie MC5100, Série MC280, Série MC200, Série MC100, Série MC80
MODBUS RTUPorta sérieSérie MC5100, Série MC280, Série MC200, Série MC100, Série MC80
YaskawaDicas:A Yaskawa utiliza principalmente o protocolo MEMOBUS para comunicação (suporta S7).
MemobusEthernetSérie GL120/130, Série GL60, Série MP3000, Série MP2300, Série Z1000
FatekDicas:A Fatek utiliza principalmente o protocolo Fatek para a comunicação.
FatekPorta sérieSérie FBs
VigorDicas:O Vigor utiliza principalmente o protocolo privado VS para a comunicação.
VSPorta sérieSérie VS
FujiDicas:A Fuji utiliza principalmente o protocolo SPH/SPB para as comunicações.
SPHEthernetSérie SPH
SPBPorta sérieSérie SPB

 

Bandas 4G

*Você pode entrar em contato com o serviço de atendimento ao cliente para selecionar o módulo correspondente para substituição.

Tipo de móduloBandas de frequência
EC200A-CNLTE FDD: B1/B3/B5/B8
LTE TDD: B34/B38/B39/B40/B41
UMTS WCDMA: B1/B5/B8
EC200A-EULTE FDD: B1/B3/B5/B7/B8/B20/B28
LTE TDD: B38/B40/B41
UMTS WCDMA: B1/B5/B8
EC200A-AULTE FDD: B1/B2/B3/B4/B5/B7/B8/B28/B66
LTE TDD: B40
UMTS WCDMA: B1/B2/B4/B5/B8

 

Descarregar

Candidatar-se a amostras de produtos