EG8208 8-Port RS485 Edge Gateway - 4G LTE Modbus To MQTT/JSON Converter - IOTROUTER
Une fois toutes les 5 minutes

EG8208 8-Port RS485 Edge Gateway – 4G LTE Modbus to MQTT/JSON Converter

Serial to Ethernet Converter for Industrial Networks

A versatile gateway for connecting multiple RS485 devices to Ethernet networks, ideal for complex industrial deployments and IoT integration.





Protocoles de l'industrie
CJ188 / DLT645 / HJ212 / Modbus / OPC UA / BACnet, etc.
Protocoles de réseau
MQTT / HTTP / TCP / UDP / WEBSOCKET
INTERFACE
8*RS485, 8*DO, 1*WAN/LAN
COMMUNICATION
LTE 4G

Catégories : , Acheter sur Alibaba

Description

The EG8208 is an industrial-grade 8-Port RS485 Edge Gateway designed for multi-device industrial networking in demanding environments. It enables bidirectional transparent data transmission between RS485 and Ethernet, while supporting Modbus RTU to TCP conversion, multi-host polling, and user-defined JSON data reporting for flexible integration.

With built-in Node-RED, multiple operating modes, and support for a wide range of PLC protocols, the EG8208 is well-suited for factory automation, outdoor deployments, and industrial IoT applications, enabling stable and efficient data connectivity and protocol integration across diverse scenarios.


Key Features

iiotGateway_keyfeatures_01

RS485 Serial Interface

8 isolated channels, 1200–115200 bps configurable per port

iiotGateway_keyfeatures_02

Multiple Operational Modes

Supports TCP Server/Client, UDP, MQTT, and HTTP Client modes

iiotGateway_keyfeatures_03

Remote Virtual LAN

Secure VPN for remote PLC program upload/download

iiotGateway_keyfeatures_04

Multi-Protocole

Seamless communication across different protocols

iiotGateway_keyfeatures_05

Low-Code Development

Drag-and-drop logic for serial data processing and control

iiotGateway_keyfeatures_06

Gestion à distance

Remote configuration, debugging, and program updates

iiotGateway_keyfeatures_07

Reliable Connectivity

4G / Ethernet / Wi-Fi with auto failover

iiotGateway_keyfeatures_08

Industrial-Grade

Operates from −40°C to 85°C with 9–36V wide voltage input

* Soutien OEM/ODM, contact customer service for details.


EG8208 02


EG Series Products

All gateways in the EG series share a highly consistent operating method. Differences between models are mainly reflected in hardware interfaces, and the corresponding variations are limited to the presence or absence of certain functional nodes.

EG Series8200 Pro82008200 Mini8200 Lite82082000
Key FeatureHaute performanceMulti-interfaceStandard VersionDIN-rail VersionCNC VersionIEC104 VersionLow Cost8 Serial PortsPasserelle LoRa
ProcessorOcta-core A55 @1.8GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzA7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHz
Mémoire2GB512MB512MB512MB512MB512MB256MB512MB512MB
eMMC16GB4GB4GB4GB4GB4GB4GB4GB4GB
Carte SDMax 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)×Max 128GB (optional)Max 128GB (optional)
4G×√ (optional)√ (optional)
5G√ (optional)××××××××
HDMI××××××××
Ports Ethernet1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN/LAN1×WAN/LAN1×WAN/LAN
LoRa××××××××
Wi-FiDual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6×××
GPS××××××××
USB2×USB 2.01×USB 2.0×××××××
RTC×
RS485322222281
RS232111111×××
CAN×2×××××××
DO22×××××8×
DI22×××××××
AO2××××××××
AI2××××××××
Tension de fonctionnement9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V
Courant d'exploitation500mA@12V280mA/12V150mA/12V150mA/12V150mA/12V150mA/12V60mA/12V170mA/12V180mA/12V
CertificationCECECECECECECECECE
Température de fonctionnement-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-20 ~ 85°C-40 ~ 85°C-40 ~ 85°C
O&M à distance
Gestion à distance
Mise à jour à distance
Virtual Network Interface
Port série virtuel
Local Database×
Programmation visuelle
PLC Protocol×××
CNC Protocol××××××××
IEC 60870-5-104××××××××
Web Configuration××××××××
Protocoles de l'industrieCJ188/DLT645/HJ212/Modbus/OPC UA*/BACnet*/etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical
Protocoles de réseauMQTT / HTTP / TCP / UDP / WebSocket / Alibaba Cloud IoT Platform / OneNET / etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical

Quick Access to EG Series Products →


Main Functions

EG8208 8-Port RS485 Edge Gateway01

Massive PLC Protocols

– Highly Compatible – 

The EG8208 8-Port RS485 Edge Gateway supports docking various mainstream CNC brands, including but not limited to SIEMENS, MELSEC, Mazak, Heiden-hain, Haas, KND, LNC, Fanuc, Brother, GSK, CITIZEN, SYNTEC, and so on. Please contact us to get the list of the specific CNC protocol models.

Multi-Protocol Support

This gateway supports standard industrial protocols, including Modbus, MQTT, OPC UA/DA, HJ212, and IEC104, enabling seamless integration with SCADA systems, cloud platforms, and other third-party applications.
For non-standard protocols, custom parsing and logic can be implemented using JavaScript (JS).

EG8208 8-Port RS485 Edge Gateway02
EG8208

8-Channel Independent Power Supply

8-channel independent power supply for sensors. The external power supply voltage is equal to the gateway power supply voltage. The maximum current per channel is 1A, and the maximum total current is 4A.

Encryption Transmission

Use two-way certificate verification + SSL encryption transmission mechanism to ensure data security. Transmission protocols such as TCP, HTTP, and MQTT can all achieve anti-eavesdropping, anti-tampering, and anti-impersonation.

EG8208 8-Port RS485 Edge Gateway04
EG8208 8-Port RS485 Edge Gateway07

Remote Virtual LAN/ Port série

– PLC Remote Upload & Download –

With Virtual Ethernet and Virtual Serial Port, engineers can remotely access PLCs, HMIs, and serial devices for programming, maintenance, and debugging as if they were on the same local network.

Gestion à distance

With EGManager remote management software, this multi-port gateway can realize remote configuration, remote debugging, remote diagnosis, remote program update, and other functions for the equipment on site.

CNC Gateway for Industrial Data Acquisition and Protocol Conversion02
EG8208 8-Port RS485 Edge Gateway08

Drag & Drop Programming

Built on Node-RED drag-and-drop visual programming, EG8208 supports all traditional serial server functions without communication restrictions. It enables users to customize data formats and logic, seamlessly integrating sensors and third-party platforms via MQTT/JSON to build simple, flexible, and efficient IoT automation workflows.


Multiple Working Modes

1. TCP Server

Monitor the set port and wait for a TCP client connection. Transmit the data sent by the serial device transparently to all successfully connected client-side.

TCP Server

2. TCP Client

Initiate a TCP connection to the set IP address. lf fail, EG8208 will continue to try to reconnect until it succeeds. lf connect well, the server can transparently transmit data bidirectionally with the serial port device.

TCP Client

3. UDP Mode

Send the serial device data to the specified lP network device via UDP mode. EG8208 also monitors the port and forwards all received data to the serial device.

UDP Mode

4. MQTT Mode

Support communication between serial data and servers through the MQTT protocol.

MQTT Mode

5. HTTP Client

Support submission of serial data to designated servers via HTTP.

HTTP Client

6. Simultaneous Access From Multiple Hosts

Allow multiple computers to access the same serial port device at the same time
Only in the question-and-answer query mode.

Simultaneous Access From Multiple Hosts


8-Port RS485 Edge Gateway Applications

1. Multi-Channel Serial Device Centralized Collection and Reporting

This is the most typical application of the EG8208 8-Port RS485 edge gateway. In smart water, environmental monitoring, and smart agriculture, there are often numerous distributed 485 devices on site, such as flow meters, water quality sensors, and weather stations. The EG8208 can connect all these devices in one go, collect and process the data centrally, and upload it to the cloud platform or data center via 4G or wired network.

2. Industrial On-Site Protocol Conversion and Data Integration

The gateway comes with a rich protocol library, supporting industry protocols such as Modbus, DLT645, and CJ188. It also supports communication protocols of mainstream PLCs, including Siemens and Mitsubishi. The EG8208 can convert data from different protocols into a unified format (e.g., MQTT, HTTP), making it easy to interface with upper-level systems such as MES and SCADA.

3. Networking with IO Acquisition Terminals to Build a Distributed System

The EG8208 can act as a central gateway and network with multiple remote IO acquisition terminals like the ET3410 via the MQTT protocol, forming a distributed monitoring system with wider coverage and enabling remote access to distributed digital and analog signals.

The Core Advantage

The EG8208 is an industrial communication hub designed for multi-serial scenarios, especially suitable for cases where numerous distributed serial instruments and sensors need to be centrally networked and intelligently processed.


FAQ

Q1: Is the EG8208 industrial-grade and suitable for harsh environments?

A1: Yes, the EG8208 is a true industrial-grade gateway:

    • Wide operating temperature: -40℃ to 85℃, suitable for extreme conditions.

    • Rugged and durable: Enclosure made of galvanized steel, supports DIN35MM standard rail mounting, with a compact footprint of 133 × 106 × 25 mm.

    • Strong anti-interference capability: Features ESD and surge protection, and has passed relevant EMC testing.

Q2: Does it support other networking options besides 4G?

A2: Yes. The EG8208 comes with a standard 4G full-network module (optional Quectel CAT4 module) and also offers a 10/100/1000M adaptive Ethernet port (WAN/LAN), enabling flexible wired or wireless Internet access depending on the on-site network conditions.


Product Size and Ports

EG8208


Packing List

EG8208_8_11zon


passerelle de périphérie industrielle

Protocoles PLC

Protocoles PLC de la passerelle Edge Computing de la série EG8000

La passerelle est classée selon la structure hiérarchique marque->protocole->modèle, et des modèles d'API représentatifs sont sélectionnés pour être testés dans chaque catégorie. Les autres modèles pris en charge proviennent des documents officiels. Remarque : la passerelle prend en charge le protocole standard MOBUDS RTU/TCP, qui est pris en charge par tous les automates courants. (Par exemple, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

MarqueProtocoleInterfaceModèle PLC
SIEMENSConseils :Siemens, dans la vente de la série, prend en charge la communication par protocole S7, il est recommandé d'utiliser la communication par protocole S7.
S7EthernetSérie S7-S200smart, Série S7-S200, Série S7-S300, Série S7-S400, Série S7-S1200, Série S7-S1500
PPIPort sérieSérie S7-200
MELSECConseils :Mitsubishi utilise principalement le protocole MC pour la communication, les séries FX5, FX3, Q, etc. sont testées.
EtherNet/IPEthernetSérie FX5-ENET/IP, série RJ71EIP91, série QJ71EIP71
MC-1E/MC-3EEthernetSérie FX5, série RJ71EN71, série RnENCPU, série LJ71E71, série QJ71E71, série QnUCPU, série FX3
MODBUS TCPEthernetSérie FX5, série RJ71EN71, série RnENCPU, série LJ71E71, série QJ71E71
MC-3CPort sérieSérie FX5, série RJ71C24, série LJ71C24, série QJ71C24
MODBUS RTUPort sérieSérie FX5, série RJ71C24, série LJ71C24, série QJ71C24, série FX3
FxLinksPort sérieSérie FX3, Série FX2, Série FX1, Série FX0
FxSerialPort sérieSérie FX3, Série FX2, Série FX1, Série FX0
OMRONConseils :Omron utilise principalement le protocole Fins pour la communication.
EtherNet/IPEthernetSérie NX7, série NX1, série NX1P, série NJ, CJ1W-EIP21
PalmesEthernetSérie CP, série CS, série CJ, série CV
HostLinkPort sérieSérie CP, série CS, série CJ, série CV, série C
LSisConseils :LS utilise principalement le protocole FEnet/Cnet pour la communication.
XGB FEnetEthernetSérie XGB (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetSérie XGT (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetPort sérieSérie XGB (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetPort sérieSérie XGT (XGL-CH2A, XGL-C21A, XGL-C41A)
MarqueProtocoleInterfaceModèle PLC
AllenBrandlyConseils :Rockwell utilise principalement le protocole CIP, DF1 pour la communication.
EtherNet/IPEthernetSérie ControlLogix, série CompactLogix, série Micro800 (820, 850, 870)
DF1Port sérieSérie ControlLogix, série CompactLogix (module 5069-SERIAL), série Micro800 (820, 830, 850, 870)
Série SLC (500, 5/03, 5/04, 5/05) , Série Micro-Logix (1000, 1100, 1200, 1500)
BeckhoffConseils :Beckhoff utilise principalement le protocole ADS pour la communication.
ADSEthernetSérie CX, TwinCAT2, TwinCAT3
InovanceConseils :Inovance adopte principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie AC, série AM, série H5U, série H3U
MODBUS RTUPort sérieSérie AC, Série AM, Série H5U, Série H3U, Série H1U
KeyenceConseils :Keyence utilise principalement le protocole KV pour la communication.
MC-3EEthernetSérie KV-8000, Série KV-7000, Série KV-5500, Série KV-5000
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A et autres unités Ethernet
KVEthernet
KVPort sérieKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicConseils :Panasonic utilise principalement le protocole Mewtocol pour la communication.
MC-3EEthernetSérie FP7, série FP0H, série FP-XH
MewtocolEthernetSérie FP7, série FP0H, série FP-XH
MewtocolPort sérieSérie FP7, série FP0H, série FP-XH, série FP-X0, série FP0R
DeltaConseils :Delta utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie AH, série AS, série AX-3, série DVP (Ethernet intégré)
MODBUS RTUPort sérieSérie AH, Série AS, Série AX-3, Série DVP
XinJEConseils :XinJE utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie CCSD, série XA, série XS, série XG, série XL
MODBUS RTUPort sérieSérie CCSD, série XA, série XS, série XG, série XL, série XC, série XD
MegMeetConseils :MegMeet utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie MC5100, série MC280, série MC200, série MC100, série MC80
MODBUS RTUPort sérieSérie MC5100, série MC280, série MC200, série MC100, série MC80
YaskawaConseils :Yaskawa utilise principalement le protocole MEMOBUS pour la communication (prend en charge le S7).
MemobusEthernetSérie GL120/130, Série GL60, Série MP3000, Série MP2300, Série Z1000
FatekConseils :Fatek utilise principalement le protocole Fatek pour la communication.
FatekPort sérieSérie FBs
VigueurConseils :Vigor utilise principalement le protocole privé VS pour communiquer.
VSPort sérieSérie VS
FujiConseils :Fuji utilise principalement le protocole SPH/SPB pour les communications.
SPHEthernetSérie SPH
SPBPort sérieSérie SPB

Fiche technique

Configuration de base UNITÉ CENTRALE2 cœurs A7@1.2G
Mémoire512M
EMMC4G
StockageCarte SD128G max(Optionnel)
4GModuleQuectel-CAT4(4G/Ethernet Optionnel)
Bande de fréquenceLTE-FDD:B1/B3/B5/B8
LTE-TDD:B34/B38/B39/B40/B41
WCDMMA:B1/B5/B8
GSM:900/1800MHz
Puissance d'émissionLTE-TDD : classe 3 (23 dBm ±2 dB)
LTE-FDD : classe 3 (23 dBm ±2 dB)
WCDMA : Classe 3 (24 dBm +1/-3 dB)
PCS1900 8-PSK : Classe E2 (26 dBm ±3 dB)
DCS1800 8-PSK : Classe E2 (26 dBm ±3 dB)
EGSM900 8-PSK : Classe E2 (27 dBm ±3 dB)
GSM850 8-PSK : Classe E2 (27 dBm ±3 dB)
PCS1900 : Classe 1 (30 dBm ±2 dB)
DCS1800 : Classe 1 (30 dBm ±2 dB)
EGSM900 : Classe 4 (33 dBm ±2 dB)
GSM850 : Classe 4 (33 dBm ±2 dB)
Largeur de bande
(Le taux maximum est de
théorique, et le
le taux réel se réfère à la
configuration du réseau).
LTE-FDD:Max 150Mbps(DL)/Max 50Mbps(UL)
LTE-TDD:Max 130Mbps(DL)/Max 30Mbps(UL)
EthernetWAN/LAN1 * 10M/100M/1000M auto-adaptatif
RS485Nombre d'interfaces8 voies
TerminauxA、B
Débit en bauds2400~921600bps
Bits de données 7、8
Bits d'arrêt1、2
Chiffre de contrôle NONE(No Check Digit)EVEN(Even Check)ODD(Odd Check)
Protection de l'environnementAntistatique, Anti-surge
RTCHorloge locale
Paramètres électriquesAuthentificationCE
Adaptateur12V/2A
Tension de fonctionnement9~36V
Courant d'exploitation170mA/12V
Paramètres environnementauxTempérature de fonctionnement-40~85℃
Température de stockage-40~85℃
Environnement Humidité0~95%RH(No Condensation)
Humidité du magasin0~95%RH(No Condensation)
Paramètres mécaniquesTaille133*106*36mm
Matériau du boîtier Acier galvanisé
InstallationFixé par vis
Dissipation de la chaleurRefroidissement passif
Bouton RESTAppuyer sur la touche et la maintenir enfoncée pendant 10 secondes pour réinitialiser
EMCDécharge électrostatiqueNiveau de décharge de l'air3 ±8KV
Contact Niveau de décharge2 ±4KV
Surtensionniveau2 ±1KV
Burst(EFT) (éclatement) niveau2 ±1KV
Caractéristiques du logicielO&M à distance
Gestion à distance
Mises à jour à distance
Port de réseau virtuel
Port série virtuel
Bases de données de séries chronologiques
Programmation visuelle
Protocoles PLC
Protocoles de l'industrieCJ188 / DLT645 / HJ212 / Modbus / OPC UA / BACnet, etc.
Protocoles de réseauMQTT / HTTP / TCP / UDP / WEB SOCKET / Alibaba Cloud IoT Platform / OneNET, etc.
SystèmeSystèmeLinux

Bandes 4G

*Vous pouvez contacter le service clientèle pour sélectionner le module de remplacement correspondant.

Style du moduleBandes de fréquences
EC800K-CNLTE FDD : B1/B3/B5/B8
LTE TDD : B34/B38/B39/B40/B41
EG800K-EULTE FDD : B1/B3/B5/B7/B8/B20/B28
EG800K-LALTE FDD : B2/B3/B4/B5/B7/B8/B28/B66

Télécharger

Demande d'échantillons de produits