EG8200Mini – DIN-Rail PLC Gateway for Industrial Data Acquisition

DIN-Rail PLC Gateway for Industrial IoT

An industrial PLC gateway designed for DIN-rail mounting in control cabinets, enabling reliable PLC-to-IoT connectivity and protocol conversion.

Video Video





Protocoles de l'industrie
CJ188/DLT645/HJ212/1EC104/Modbus/OPC UA/BACnet
Protocoles de réseau
MQTT/ HTTP /TCP/ UDP /WEBSOCKET

INTERFACE

2*RS485, 1*RS232, 1*WAN, 1*LAN
COMMUNICATION
LTE 4G, RJ45, WiFi

Catégories : , Buy on Alibaba

Description

EG8200Mini DIN-Rail PLC Gateway is a compact and cost-effective industrial PLC gateway designed for DIN-rail mounting in control cabinets. With built-in Node-RED visual programming and ready-to-use nodes for mainstream PLC brands such as Siemens, Mitsubishi (MELSEC), Omron, LS Electric, Allen-Bradley, Delta, etc., it enables fast integration, protocol conversion, and flexible data processing. The gateway supports remote device management and maintenance, making it suitable for industrial automation systems, control cabinets, and factory environments.

Key Features

iiotGateway_keyfeatures_01

Compact Design

Small footprint for easy deployment in various environments

iiotGateway_keyfeatures_02

Low-Code Development

Visual programming with built-in Node-RED

iiotGateway_keyfeatures_03

Remote Virtual LAN

Virtual LAN for remote PLC access and program upload/download

iiotGateway_keyfeatures_04

Multi-Protocole

Seamless communication across industrial protocols

iiotGateway_keyfeatures_05

Flexible Edge Processing

Local data analysis and logic execution at the edge

iiotGateway_keyfeatures_06

Gestion à distance

Remote configuration, debugging, and program updates

iiotGateway_keyfeatures_07

Reliable Connectivity

4G / Ethernet / Wi-Fi with auto failover

iiotGateway_keyfeatures_08

Industrial-Grade

Operates from −40°C to 85°C with 9–36V wide voltage input

* Soutien OEM/ODM, contact customer service for details.


5G industrial edge computing gateway


EG Series Products

All gateways in the EG series share a highly consistent operating method. Differences between models are mainly reflected in hardware interfaces, and the corresponding variations are limited to the presence or absence of certain functional nodes.

EG Series8200 Pro82008200 Mini8200 Lite82082000
Key FeatureHaute performanceMulti-interfaceStandard VersionDIN-rail VersionCNC VersionIEC104 VersionLow Cost8 Serial PortsPasserelle LoRa
ProcessorOcta-core A55 @1.8GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzA7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHz
Mémoire2GB512MB512MB512MB512MB512MB256MB512MB512MB
eMMC16GB4GB4GB4GB4GB4GB4GB4GB4GB
Carte SDMax 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)×Max 128GB (optional)Max 128GB (optional)
4G×√ (optional)√ (optional)
5G√ (optional)××××××××
HDMI××××××××
Ethernet Ports1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN/LAN1×WAN/LAN1×WAN/LAN
LoRa××××××××
Wi-FiDual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6×××
GPS××××××××
USB2×USB 2.01×USB 2.0×××××××
RTC×
RS485322222281
RS232111111×××
CAN×2×××××××
DO22×××××8×
DI22×××××××
AO2××××××××
AI2××××××××
Tension de fonctionnement9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V
Courant d'exploitation500mA@12V280mA/12V150mA/12V150mA/12V150mA/12V150mA/12V60mA/12V170mA/12V180mA/12V
CertificationCECECECECECECECECE
Température de fonctionnement-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-20 ~ 85°C-40 ~ 85°C-40 ~ 85°C
O&M à distance
Gestion à distance
Mise à jour à distance
Virtual Network Interface
Port série virtuel
Local Database×
Programmation visuelle
PLC Protocol×××
CNC Protocol××××××××
IEC 60870-5-104××××××××
Web Configuration××××××××
Protocoles de l'industrieCJ188/DLT645/HJ212/Modbus/OPC UA*/BACnet*/etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical
Protocoles de réseauMQTT / HTTP / TCP / UDP / WebSocket / Alibaba Cloud IoT Platform / OneNET / etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical

Quick Access to EG Series Products →


Main Functions

DIN-Rail PLC Gateway1_1_11zon

Wide PLC Compatibility

– Millisecond-Level Data Acquisition – 

Supports communication with major PLC brands, including Siemens, Mitsubishi (MELSEC), Omron, Allen-Bradley, Beckhoff, Inovance, Keyence, Panasonic, Delta, and more, enabling fast PLC data acquisition for edge applications. You can contact the customer service for a list of the specific PLC protocol models.

Multi-Protocol Support

– Third-Party Platform Integration –

Supports standard industrial protocols including Modbus, MQTT, OPC UA/DA, HJ212, and IEC104, enabling seamless integration with SCADA systems, cloud platforms, and other third-party applications.
For non-standard protocols, custom parsing and logic can be implemented using JavaScript (JS).

DIN-Rail PLC Gateway2_2_11zon
DIN-Rail PLC Gateway3_3_11zon

Gestion à distance

The EG8200 series remote management software supports remote configuration, debugging, diagnosis, and program updates for on-site devices.

Remote Virtual LAN

– PLC Remote Upload & Download –

With Virtual Ethernet and Virtual Serial Port, engineers can remotely access PLCs, HMIs, and serial devices for programming, maintenance, and debugging as if they were on the same local network.

DIN-Rail PLC Gateway5_5_11zon
DIN-Rail PLC Gateway6_6_11zon

Drag & Drop Programming

– Low-code visual programming –

Using Node-RED visual programming, EG8200Mini allows users to build automation workflows through drag-and-drop configuration. It supports integration with sensors and third-party platforms via protocols such as MQTT and JSON.


The EG8200Mini PLC gateway provides both interfaces, allowing industrial devices to be connected directly to the gateway and their data integrated into monitoring systems or industrial IoT platforms.

2. PLC Protocol Integration for Industrial Systems

Many industrial platforms require direct access to PLC data rather than simple serial data forwarding. The EG8200Mini PLC gateway supports communication with mainstream PLC protocols, allowing the gateway to collect and parse PLC data and integrate it with SCADA systems, industrial software, or IIoT platforms without additional protocol development.

3. Control Cabinet Integration for Industrial Systems

In factory automation and industrial systems, devices are typically installed inside control cabinets to ensure standardized wiring, protection, and centralized management.

With DIN-rail mounting support, the EG8200Mini can be easily installed inside control cabinets alongside PLCs, power supplies, and other industrial devices, enabling a clean layout and efficient system integration.

Its support for Ethernet and Wi-Fi connectivity also simplifies network integration, making it suitable for factory automation, equipment monitoring, and industrial IoT deployments.

The Core Advantage

The EG8200Mini Industrial PLC Gateway is designed for industrial environments that require reliable PLC communication, protocol integration, and standardized installation.

With RS232 and RS485 connectivity, built-in PLC protocol support, and Node-RED integration, it enables efficient data acquisition and system integration within control cabinets and industrial automation systems.


FAQ

Q1. What protocols does the EG8200Mini Industrial DIN-Rail PLC Gateway support?

A1:
The EG8200Mini supports a wide range of industrial communication protocols for device integration and data acquisition, including:

• Modbus RTU / Modbus TCP
• PLC communication protocols such as SIEMENS, Mitsubishi (MELSEC), OMRON, LS Electric, Allen-Bradley, Delta, and other mainstream PLC brands
• Industrial and IoT protocols including MQTT, OPC UA / OPC DA, HJ212, and IEC104
• Common network communication protocols such as HTTP, TCP, UDP, and WebSocket

For non-standard or proprietary protocols, users can implement custom parsing and logic through JavaScript (JS).

Q2. Does the EG8200Mini support Node-RED or low-code programming?

A2:
Yes. The EG8200Mini includes a built-in Node-RED visual programming environment, allowing users to create automation workflows through drag-and-drop configuration.

Engineers can implement PLC data acquisition, protocol conversion, data processing, and cloud integration without complex programming. For advanced requirements, JavaScript function nodes can also be used for custom logic and data handling.


Product Size and Interfaces

DIN-Rail PLC Gateway7_7_11zon


Packing List

DIN-Rail PLC Gateway8_8_11zon


passerelle de périphérie industrielle

Fiche technique

MatérielUNITÉ CENTRALE2*Cortex-A7@1.2GHz
Mémoire512M
EMMC4G (MLC)
Carte SDJusqu'à 128G (influxdb préinstallé)
RTCHorloge en temps réel
Sans filLTE Cat1
WAN1*10M/100M/1000M Auto-adaptatif
LAN1*10M/100M Auto-adaptatif
WiFiAP+Station
RS4852* RS485
RS2321* RS232
LEDPersonnalisable
Paramètres électriquesTension de fonctionnement9~36V
Courant d'exploitation150mA/12V
Adaptateur12V/2A
Protection de l'alimentationAntistatique, anti-surtension, anti-retour
CertificationCE/ROHS/FCC
Paramètres environnementauxTempérature de fonctionnement-40~85℃
Température de stockage-40~85℃
Humidité de fonctionnement0-95%RH(No Condensation)
Méthode de refroidissementDissipateur thermique / silicone de dissipation
Paramètres mécaniquesTaille115*90*35mm/125*95*32mm
Poids<1kg
MatériauAlliage de zinc
Paramètres du logicielOpérationsPrise en charge de la configuration, de la mise à jour et de la gestion à distance
VPNPrise en charge de la pénétration de l'intranet/du téléchargement à distance de l'automate/du port série virtuel
Informatique de pointePrise en charge de la programmation visuelle, du développement en code zéro, de la programmation par glisser-déposer, du développement secondaire, de l'absence de compilation
Stockage des donnéesPrise en charge des files d'attente, de la lecture et de l'écriture de fichiers, du transfert déconnecté et de l'influxdb.
Accord industrielPrise en charge de plusieurs protocoles industriels
Protocole de réseauMQTT/HTTP/TCP/UDP

Protocoles PLC

Protocoles PLC de la passerelle Edge Computing de la série EG8000

La passerelle est classée selon la structure hiérarchique marque->protocole->modèle, et des modèles d'API représentatifs sont sélectionnés pour être testés dans chaque catégorie. Les autres modèles pris en charge proviennent des documents officiels.
Remarque : la passerelle prend en charge le protocole standard MOBUDS RTU/TCP, qui est pris en charge par tous les automates courants (par exemple, HollySys, Haiwell, Yokogawa, Runpower, etc. (Par exemple, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

MarqueProtocoleInterfaceModèle PLC
SIEMENSConseils :Siemens, dans la vente de la série, prend en charge la communication par protocole S7, il est recommandé d'utiliser la communication par protocole S7.
S7EthernetSérie S7-S200smart, Série S7-S200, Série S7-S300, Série S7-S400, Série S7-S1200, Série S7-S1500
PPIPort sérieSérie S7-200
MELSECConseils :Mitsubishi utilise principalement le protocole MC pour la communication, les séries FX5, FX3, Q, etc. sont testées.
EtherNet/IPEthernetSérie FX5-ENET/IP, série RJ71EIP91, série QJ71EIP71
MC-1E/MC-3EEthernetSérie FX5, série RJ71EN71, série RnENCPU, série LJ71E71, série QJ71E71, série QnUCPU, série FX3
MODBUS TCPEthernetSérie FX5, série RJ71EN71, série RnENCPU, série LJ71E71, série QJ71E71
MC-3CPort sérieSérie FX5, série RJ71C24, série LJ71C24, série QJ71C24
MODBUS RTUPort sérieSérie FX5, série RJ71C24, série LJ71C24, série QJ71C24, série FX3
FxLinksPort sérieSérie FX3, Série FX2, Série FX1, Série FX0
FxSerialPort sérieSérie FX3, Série FX2, Série FX1, Série FX0
OMRONConseils :Omron utilise principalement le protocole Fins pour la communication.
EtherNet/IPEthernetSérie NX7, série NX1, série NX1P, série NJ, CJ1W-EIP21
PalmesEthernetSérie CP, série CS, série CJ, série CV
HostLinkPort sérieSérie CP, série CS, série CJ, série CV, série C
LSisConseils :LS utilise principalement le protocole FEnet/Cnet pour la communication.
XGB FEnetEthernetSérie XGB (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetSérie XGT (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetPort sérieSérie XGB (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetPort sérieSérie XGT (XGL-CH2A, XGL-C21A, XGL-C41A)

 

MarqueProtocoleInterfaceModèle PLC
AllenBrandlyConseils :Rockwell utilise principalement le protocole CIP, DF1 pour la communication.
EtherNet/IPEthernetSérie ControlLogix, série CompactLogix, série Micro800 (820, 850, 870)
DF1Port sérieSérie ControlLogix, série CompactLogix (module 5069-SERIAL), série Micro800 (820, 830, 850, 870)
Série SLC (500, 5/03, 5/04, 5/05) , Série Micro-Logix (1000, 1100, 1200, 1500)
BeckhoffConseils :Beckhoff utilise principalement le protocole ADS pour la communication.
ADSEthernetSérie CX, TwinCAT2, TwinCAT3
InovanceConseils :Inovance adopte principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie AC, série AM, série H5U, série H3U
MODBUS RTUPort sérieSérie AC, Série AM, Série H5U, Série H3U, Série H1U
KeyenceConseils :Keyence utilise principalement le protocole KV pour la communication.
MC-3EEthernetSérie KV-8000, Série KV-7000, Série KV-5500, Série KV-5000
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A et autres unités Ethernet
KVEthernet
KVPort sérieKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicConseils :Panasonic utilise principalement le protocole Mewtocol pour la communication.
MC-3EEthernetSérie FP7, série FP0H, série FP-XH
MewtocolEthernetSérie FP7, série FP0H, série FP-XH
MewtocolPort sérieSérie FP7, série FP0H, série FP-XH, série FP-X0, série FP0R
DeltaConseils :Delta utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie AH, série AS, série AX-3, série DVP (Ethernet intégré)
MODBUS RTUPort sérieSérie AH, Série AS, Série AX-3, Série DVP
XinJEConseils :XinJE utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie CCSD, série XA, série XS, série XG, série XL
MODBUS RTUPort sérieSérie CCSD, série XA, série XS, série XG, série XL, série XC, série XD
MegMeetConseils :MegMeet utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie MC5100, série MC280, série MC200, série MC100, série MC80
MODBUS RTUPort sérieSérie MC5100, série MC280, série MC200, série MC100, série MC80
YaskawaConseils :Yaskawa utilise principalement le protocole MEMOBUS pour la communication (prend en charge le S7).
MemobusEthernetSérie GL120/130, Série GL60, Série MP3000, Série MP2300, Série Z1000
FatekConseils :Fatek utilise principalement le protocole Fatek pour la communication.
FatekPort sérieSérie FBs
VigueurConseils :Vigor utilise principalement le protocole privé VS pour communiquer.
VSPort sérieSérie VS
FujiConseils :Fuji utilise principalement le protocole SPH/SPB pour les communications.
SPHEthernetSérie SPH
SPBPort sérieSérie SPB

Bandes 4G

* You may contact customer service to select the corresponding module for replacement.

Style du moduleBandes de fréquences
EC800K-CNLTE FDD : B1/B3/B5/B8
LTE TDD : B34/B38/B39/B40/B41
EG800K-EULTE FDD : B1/B3/B5/B7/B8/B20/B28
EG800K-LALTE FDD : B2/B3/B4/B5/B7/B8/B28/B66

Télécharger

Apply For Product Samples