  • Interface type:  8RS485/1LAN
  • Protocol support:  Modbus/PLC/RTU/TCP/MQTT/HJ212/PLC……
  • Network type:  4G
  • Features:  8 serial edge computing data bi-directional transmission of multiple modes of operation Modbus RTU/TCP transfer and customized JSON format reporting

Categories: ,

Description

EG8208 8 Serial Ports Edge Gateway is a professional 8-channel independent isolated RS485 communication controller. Modbus and JSON support, flexible TCP/IP and UDP switching, built-in monitoring, and self-diagnostic features. Widely used in industrial automation, building management, and other fields. Provide users with excellent data acquisition and device management solutions.

EG8208 01 EG8208 02 EG8208 03 EG8208 04 EG8208 05 EG8208 06 EG8208 07 EG8208 08 EG8208 09 EG8208 10 EG8208 11 EG8208 12 EG8208 13 EG8208 14 EG8208 15 EG8208 16 EG8208 17 EG8208 18 EG8208 19 EG8208 20 EG8208 21 EG8208 22 EG8208 23 EG8208 24 EG8208 25 EG8208 26

PLC Protocols

EG8000 Series Edge Computing Gateway PLC Protocols

The gateway is categorized according to the hierarchical structure of brand->protocol->model, and representative PLC models are selected for testing in each category. The rest of the supported models are from the official documents. Note: The gateway supports the standard MOBUDS RTU/TCP protocol, which is supported by all mainstream PLCs. (For example, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

BrandProtocolInterfacePLC Model
SIEMENSTips:Siemens in the sale of the series all support S7 protocol communication, it is recommended to use the S7 protocol communication.
S7EthernetS7-S200smart, S7-S200 Series, S7-S300 Series, S7-S400 Series, S7-S1200 Series, S7-S1500 Series
PPISerial portS7-200 Series
MELSECTips:Mitsubishi mainly uses MC protocol for communication, FX5 Series, FX3 Series, Q Series, etc. are tested.
EtherNet/IPEthernetFX5-ENET/IP Series, RJ71EIP91 Series, QJ71EIP71 Series
MC-1E/MC-3EEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series, QnUCPU Series, FX3 Series
MODBUS TCPEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series
MC-3CSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series
MODBUS RTUSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series, FX3 Series
FxLinksSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
FxSerialSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
OMRONTips:Omron mainly uses the Fins protocol for communication.
EtherNet/IPEthernetNX7 Series, NX1 Series, NX1P Series, NJ Series, CJ1W-EIP21
FinsEthernetCP Series, CS Series, CJ Series, CV Series
HostLinkSerial portCP Series, CS Series, CJ Series, CV Series, C Series
LSisTips:LS mainly uses FEnet/Cnet protocol for communication.
XGB FEnetEthernetXGB Series (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetXGT Series (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetSerial portXGB Series (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetSerial portXGT Series (XGL-CH2A, XGL-C21A, XGL-C41A)

PLC More

BrandProtocolInterfacePLC Model
AllenBrandlyTips:Rockwell mainly uses CIP, DF1 protocol for communication.
EtherNet/IPEthernetControlLogix Series, CompactLogix Series, Micro800 Series (820, 850, 870)
DF1Serial portControlLogix Series, CompactLogix Series (5069-SERIAL module) , Micro800 Series (820, 830, 850, 870)
SLC Series (500, 5/03, 5/04, 5/05) , Micro-Logix Series (1000, 1100, 1200, 1500)
BeckhoffTips:Beckhoff mainly uses the ADS protocol for communication.
ADSEthernetCX Series, TwinCAT2, TwinCAT3
InovanceTips:Inovance mainly adopts MODBUS protocol for communication.
MODBUS TCPEthernetAC Series, AM Series, H5U Series, H3U Series
MODBUS RTUSerial portAC Series, AM Series, H5U Series, H3U Series, H1U Series
KeyenceTips:Keyence mainly uses the KV protocol for communication.
MC-3EEthernetKV-8000 Series, KV-7000 Series, KV-5500 Series, KV-5000 Series
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A and other Ethernet units
KVEthernet
KVSerial portKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicTips:Panasonic mainly uses the Mewtocol protocol for communication.
MC-3EEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolSerial portFP7 Series, FP0H Series, FP-XH Series, FP-X0 Series, FP0R Series
DeltaTips:Delta mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetAH Series, AS Series, AX-3 Series, DVP Series (built-in Ethernet)
MODBUS RTUSerial portAH Series, AS Series, AX-3 Series, DVP Series
XinJETips:XinJE mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetCCSD Series, XA Series, XS Series, XG Series, XL Series
MODBUS RTUSerial portCCSD Series, XA Series, XS Series, XG Series, XL Series, XC Series, XD Series
MegMeetTips:MegMeet mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
MODBUS RTUSerial portMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
YaskawaTips:Yaskawa mainly uses the MEMOBUS protocol for communication (supports S7) .
MemobusEthernetGL120/130 Series, GL60 Series, MP3000 Series, MP2300 Series, Z1000 Series
FatekTips:Fatek mainly uses the Fatek protocol for communication.
FatekSerial portFBs Series
VigorTips:Vigor mainly uses the VS private protocol for communication.
VSSerial portVS Series
FujiTips:Fuji mainly uses the SPH/SPB protocol for communications.
SPHEthernetSPH Series
SPBSerial portSPB Series

4G bands

*You may contact customer service to select the corresponding module for replacement.

Module TyleFrequency Bands
EC800K-CNLTE FDD: B1/B3/B5/B8
LTE TDD: B34/B38/B39/B40/B41
EG800K-EULTE FDD: B1/B3/B5/B7/B8/B20/B28
EG800K-LALTE FDD: B2/B3/B4/B5/B7/B8/B28/B66

Datasheet

Core Configuration CPU2 Cores A7@1.2G
Memory512M
EMMC4G
StorageSD card128G max(Optional)
4GModuleQuectel-CAT4(4G/Ethernet Optional)
Frequency BandLTE-FDD:B1/B3/B5/B8
LTE-TDD:B34/B38/B39/B40/B41
WCDMMA:B1/B5/B8
GSM:900/1800MHz
Transmit PowerLTE-TDD: Class 3 (23 dBm ±2 dB)
LTE-FDD: Class 3 (23 dBm ±2 dB)
WCDMA: Class 3 (24 dBm +1/-3 dB)
PCS1900 8-PSK: Class E2 (26 dBm ±3 dB)
DCS1800 8-PSK: Class E2 (26 dBm ±3 dB)
EGSM900 8-PSK: Class E2 (27 dBm ±3 dB)
GSM850 8-PSK: Class E2 (27 dBm ±3 dB)
PCS1900: Class 1 (30 dBm ±2 dB)
DCS1800: Class 1 (30 dBm ±2 dB)
EGSM900: Class 4 (33 dBm ±2 dB)
GSM850: Class 4 (33 dBm ±2 dB)
Bandwidth
(The maximum rate is
theoretical, and the
actual rate refers to the
network configuration.)
LTE-FDD:Max 150Mbps(DL)/Max 50Mbps(UL)
LTE-TDD:Max 130Mbps(DL)/Max 30Mbps(UL)
EthernetWAN/LAN1 * 10M/100M/1000M Self-Adaptive
RS485Number of Interfaces8-way
TerminalsA、B
Baud Rate2400~921600bps
Data Bits 7、8
Stop Bits1、2
Check Digit NONE(No Check Digit)EVEN(Even Check)ODD(Odd Check)
ProtectionAnti-static, Anti-surge
RTCLocal Clock
Electrical ParametersAuthenticationCE
Adapter12V/2A
Operating Voltage9~36V
Operating Current170mA/12V
Environmental ParametersOperating Temperature-40~85℃
Storage Temperature-40~85℃
Environment Humidity0~95%RH(No Condensation)
Store Humidity0~95%RH(No Condensation)
Mechanical ParametersSize133*106*36mm
Housing Material Galvanized Stee
InstallationScrew-fastened
Heat DissipationPassive Cooling
REST ButtonPress and Hold for 10s to Reset
EMCElectrostatic DischargeAir Discharge level3 ±8KV
Contact Discharge level2 ±4KV
Surgelevel2 ±1KV
Burst(EFT) level2 ±1KV
Software FeaturesRemote O&M
Remote Management
Remote Upgrades
Virtual Network Port
Virtual serial port
Time Series Databases
Visual Programming
PLC Protocols
Industry ProtocolsCJ188 / DLT645 / HJ212 / Modbus / OPC UA / BACnet, etc
Network ProtocolsMQTT / HTTP / TCP / UDP / WEB SOCKET / Alibaba Cloud IoT Platform / OneNET, etc
SystemSystemLinux

Download

Contact Us

Contact Us