EG8200Pro 5G Industrial Edge Computing Gateway For High-Performance Data Acquisition And Protocol Conversion - IOTROUTER
Search

EG8200Pro 5G Industrial Edge Computing Gateway for High-Performance Data Acquisition and Protocol Conversion

5G Industrial AI Edge Computing Gateway

Seamless PLC Protocol Conversion & Data Acquisition. A powerful 5G industrial edge computing gateway with Node-RED for edge intelligence.




Broad Protocols
Modbus RTU/TCP, MQTT, HJ212, and PLC (Siemens, Mitsubishi, Omron, etc.)
Versatile I/O
3*RS485, 1*RS232, 2*DI/DO, 2*AI/AO, HDMI, 2*USB 2.0
Edge Power
2Tops NPU for data pre-processing; 2G RAM + 16G eMMC
Connectivity
5G / 4G LTE / WiFi, Dual Gigabit Ethernet

Categories: ,

Description

EG8200Pro is a powerful 5G industrial edge computing gateway designed to simplify industrial digital transformation. 
With an 8-core Cortex-A55 CPU and integrated NPU, it combines powerful edge computing with comprehensive industrial connectivity and local visualization.


Key Features

Industrial-Grade Design

-40~85°C operation, 9–36V input, surge & ESD protection

Zero-Code Logic

Visual configuration with built-in Node-RED

Remote Virtual LAN

Secure VPN for remote PLC program upload/download

Multi-Protocol PLC

Siemens, Mitsubishi, Omron → MQTT / HTTP

Edge Intelligence

Local data analysis and logic processing with NPU

Flexible Customization

Custom logic and data formats via JavaScript

Reliable Connectivity

4G / Ethernet / Wi-Fi with auto failover

HDMI Visualization

Direct display of dashboards or SCADA screens

* Support OEM/ODM, contact customer service for details.

5G industrial edge computing gateway


Massive PLC Protocols - Millisecond Acquisition Unlimited Data Points -  The EG8200Pro 5G Ultra-Powerful Edge Computing Gateway supports docking various mainstream PLC brands, including but not limited to SIEMENS, MELSEC, OMRON, LSis, Allen-Brandly, BeckhoffInovance, Keyence, Panasonic, Delta, XinJE, MegMeet, Yaskawa, Fatek, Vigor, Fuji, and so on. You can consult with the customer service to get the list of the specific PLC protocol models.

Massive PLC Protocols

– Millisecond Acquisition Unlimited Data Points – 

The EG8200Pro 5G industrial edge computing gateway supports docking various mainstream PLC brands, including but not limited to SIEMENS, MELSEC, OMRON, LSis, Allen-Brandly, BeckhoffInovance, Keyence, Panasonic, Delta, XinJE, MegMeet, Yaskawa, Fatek, Vigor, Fuji, and so on. You can consult with the customer service to get the list of the specific PLC protocol models.

Multiple Industry Protocols

– Support Third-party Platform Docking –

 The EG8200Pro serves as a universal bridge for diverse industrial environments. It supports a vast array of standard protocols, including Modbus, MQTT, OPC UA/DA, HJ212, and IEC104, for seamless third-party platform docking. For complex, non-standard protocols, it offers the flexibility to parse and implement custom logic via JavaScript (JS).

Multiple Industry Protocols - Support Third-party Platform Docking - The EG8200Pro 5G industrial edge computing gateway serves as a universal bridge for diverse industrial environments. It supports a vast array of standard protocols, including Modbus, MQTT, OPC UA/DA, HJ212, and IEC104, for seamless third-party platform docking. For complex, non-standard protocols, it offers the flexibility to parse and implement custom logic via JavaScript (JS).
Remote Management The EG8200 series remote management software can realize remote configuration and remote debugging. remote diagnosis, remote program update, and other functions for the equipment on-site.

Remote Management

The EG8200 series remote management software can realize remote configuration and remote debugging.
remote diagnosis, remote program update, and other functions for the equipment on-site.

Remote Virtual LAN

– PLC Remote Upload & Download –

With Virtual Ethernet and Virtual Serial Port, engineers can remotely access on-site devices for PLC and HMI programming, server maintenance, and serial sensor debugging, as if they were in the same local network, improving efficiency and reducing on-site maintenance costs.

Remote Virtual LAN - PLC Remote Upload & Download - With Virtual Ethernet and Virtual Serial Port, engineers can remotely access on-site devices for PLC and HMI programming, server maintenance, and serial sensor debugging, as if they were in the same local network, improving efficiency and reducing on-site maintenance costs_5G industrial edge computing gateway
Web ConfigurationIndustrial Data Visualization for the 5G industrial edge computing gateway

Web ConfigurationIndustrial Data Visualization

– Free Quick Build HDMI Direct Out – 

This 5G industrial edge computing gateway can be configured locally or remotely through the browser, business logic, and Web configuration. Configuration components are rich and support secondary development. Users do not need to purchase configuration software to realizeon-site data acquisition, edit it into the configuration screen, and finally display it locally or remotely.

Drag & Drop Programming

– Low-code visual programming, rapid development of industrial logic –

Leveraging Node-RED visual programming and a vast library of proprietary nodes, the EG8200Pro enables lightning-fast integration with sensors and third-party platforms (via custom MQTT/JSON). This low-code approach significantly reduces development costs and time-to-market, allowing you to build a tailor-made gateway solution for any specific IIoT scenario.

EG8200Pro 5G Ultra Powerful Edge Computing Gateway06

Applications Of The 5G Industrial Edge Computing Gateway

1. Industrial Data Hub

Acting as the core gateway for factory floors, it enables simultaneous connectivity and data acquisition from nearly all major brands. Through local edge processing (filtering, alarming, and logic calculation), it delivers unified, clean data to MES or Cloud platforms, ensuring full-scale production transparency.

2. Remote O&M for Critical Infrastructure

Perfect for deployment in remote or hazardous locations such as power stations and pump houses. Over-the-Air (OTA) updates, engineers can perform remote configuration, program debugging, and fault diagnostics over the internet without being on-site, significantly enhancing operational safety and efficiency while slashing maintenance costs.

3. The Bridge for System Integration & Retrofitting

Ideal for smart transformation projects, it effortlessly converts legacy protocols (e.g., Modbus RTU) into data formats recognized by modern IoT systems (e.g., MQTT). This creates a seamless bridge between legacy hardware and modern IT infrastructure, protecting your existing investment.

The Core Advantage: The EG8200 Pro is purpose-built for large-scale, complex industrial projects that demand multi-protocol processing, edge computing, and secure remote management.


FAQ

Q1. What protocols does the EG8200Pro IIoT Gateway support?

A1: The EG8200Pro 5G industrial edge computing gateway supports a wide range of mainstream industrial and sector-specific protocols, including:
• Standard Modbus protocol
• SIEMENS / MELSEC / OMRON / LSis / Allen-Bradley PLC protocols, covering approximately 99% of mainstream PLC brands
• CJ188 / DLT645 / HJ212 / OPC UA / BACnet and other industry protocols
• Common network communication protocols, including: MQTT / HTTP / TCP / UDP / WebSocket / Alibaba Cloud IoT Platform / OneNET, etc.

For non-standard or proprietary protocols, data parsing can be implemented via custom JavaScript scripts.

Q2. Does the 5G industrial edge computing gateway support secondary development?  How to use Node-RED for PLC data acquisition on EG8200Pro?

A2: Yes. The EG8200Pro 5G industrial edge computing gateway comes with a built-in Node-RED visual development environment, allowing users to implement logic through drag-and-drop configuration. For more complex functions, JavaScript function nodes can be used to complete data acquisition, processing, and uploading without the need for low-level programming. 

Q3. What’s the difference between EC ARM open source industrial PCs and EG series edge computing gateways?

A3:

Comparison EG Series (Low-code Industrial Gateway) EC Series (Open Development Platform)
System Architecture Closed software-hardware architecture Standard Linux operating system
Development Method Low-code / graphical configuration Custom development / deep system customization
Node-RED Pre-installed, fully customized Node-RED Native Node-RED
Industrial Protocol Support Built-in industrial protocol nodes No built-in proprietary protocol nodes
Extension Method Drag-and-drop configuration of business logic Install community nodes or develop custom nodes
Target Users System integrators and application-level users Embedded system and IoT developers
Typical Scenarios Rapid deployment and project delivery System-level customization and secondary development

EG Series Product Selection Guide

All gateways in the EG series share a highly consistent operating method. Differences between models are mainly reflected in hardware interfaces, and the corresponding variations are limited to the presence or absence of certain functional nodes.

EG Series8200 Pro82008200 Mini8200 Lite82082000
Key FeatureHigh PerformanceMulti-interfaceStandard VersionDIN-rail VersionCNC VersionIEC104 VersionLow Cost8 Serial PortsLoRa Gateway
ProcessorOcta-core A55 @1.8GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzA7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHz
Memory2GB512MB512MB512MB512MB512MB256MB512MB512MB
eMMC16GB4GB4GB4GB4GB4GB4GB4GB4GB
SD CardMax 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)×Max 128GB (optional)Max 128GB (optional)
4G×√ (optional)√ (optional)
5G√ (optional)××××××××
HDMI××××××××
Ethernet Ports1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN/LAN1×WAN/LAN1×WAN/LAN
LoRa××××××××
Wi-FiDual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6×××
GPS××××××××
USB2×USB 2.01×USB 2.0×××××××
RTC×
RS485322222281
RS232111111×××
CAN×2×××××××
DO22×××××8×
DI22×××××××
AO2××××××××
AI2××××××××
Operating Voltage9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V
Operating Current500mA@12V280mA/12V150mA/12V150mA/12V150mA/12V150mA/12V60mA/12V170mA/12V180mA/12V
CertificationCECECECECECECECECE
Operating Temperature-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-20 ~ 85°C-40 ~ 85°C-40 ~ 85°C
Remote O&M
Remote Management
Remote Upgrade
Virtual Network Interface
Virtual Serial Port
Local Database×
Visual Programming
PLC Protocol×××
CNC Protocol××××××××
IEC 60870-5-104××××××××
Web Configuration××××××××
Industry ProtocolsCJ188/DLT645/HJ212/Modbus/OPC UA*/BACnet*/etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical
Network ProtocolsMQTT / HTTP / TCP / UDP / WebSocket / Alibaba Cloud IoT Platform / OneNET / etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical

Quick Access to EG Series Products →


Product Size and Interfaces

EG8200Pro 5G Ultra Powerful Edge Computing Gateway07

EG8200Pro Interface ldentification-2EG8200Pro Interface ldentification-1


Packing List

EG8200Pro 5G Ultra Powerful Edge Computing Gateway08


industrial edge gateway

PLC Protocols

EG8000 Series Edge Computing Gateway PLC Protocols

The gateway is categorized according to the hierarchical structure of brand->protocol->model, and representative PLC models are selected for testing in each category. The rest of the supported models are from the official documents. Note: The gateway supports the standard MOBUDS RTU/TCP protocol, which is supported by all mainstream PLCs. (For example, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

BrandProtocolInterfacePLC Model
SIEMENSTips:Siemens in the sale of the series all support S7 protocol communication, it is recommended to use the S7 protocol communication.
S7EthernetS7-S200smart, S7-S200 Series, S7-S300 Series, S7-S400 Series, S7-S1200 Series, S7-S1500 Series
PPISerial portS7-200 Series
MELSECTips:Mitsubishi mainly uses MC protocol for communication, FX5 Series, FX3 Series, Q Series, etc. are tested.
EtherNet/IPEthernetFX5-ENET/IP Series, RJ71EIP91 Series, QJ71EIP71 Series
MC-1E/MC-3EEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series, QnUCPU Series, FX3 Series
MODBUS TCPEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series
MC-3CSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series
MODBUS RTUSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series, FX3 Series
FxLinksSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
FxSerialSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
OMRONTips:Omron mainly uses the Fins protocol for communication.
EtherNet/IPEthernetNX7 Series, NX1 Series, NX1P Series, NJ Series, CJ1W-EIP21
FinsEthernetCP Series, CS Series, CJ Series, CV Series
HostLinkSerial portCP Series, CS Series, CJ Series, CV Series, C Series
LSisTips:LS mainly uses FEnet/Cnet protocol for communication.
XGB FEnetEthernetXGB Series (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetXGT Series (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetSerial portXGB Series (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetSerial portXGT Series (XGL-CH2A, XGL-C21A, XGL-C41A)
BrandProtocolInterfacePLC Model
AllenBrandlyTips:Rockwell mainly uses CIP, DF1 protocol for communication.
EtherNet/IPEthernetControlLogix Series, CompactLogix Series, Micro800 Series (820, 850, 870)
DF1Serial portControlLogix Series, CompactLogix Series (5069-SERIAL module) , Micro800 Series (820, 830, 850, 870)
SLC Series (500, 5/03, 5/04, 5/05) , Micro-Logix Series (1000, 1100, 1200, 1500)
BeckhoffTips:Beckhoff mainly uses the ADS protocol for communication.
ADSEthernetCX Series, TwinCAT2, TwinCAT3
InovanceTips:Inovance mainly adopts MODBUS protocol for communication.
MODBUS TCPEthernetAC Series, AM Series, H5U Series, H3U Series
MODBUS RTUSerial portAC Series, AM Series, H5U Series, H3U Series, H1U Series
KeyenceTips:Keyence mainly uses the KV protocol for communication.
MC-3EEthernetKV-8000 Series, KV-7000 Series, KV-5500 Series, KV-5000 Series
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A and other Ethernet units
KVEthernet
KVSerial portKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicTips:Panasonic mainly uses the Mewtocol protocol for communication.
MC-3EEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolSerial portFP7 Series, FP0H Series, FP-XH Series, FP-X0 Series, FP0R Series
DeltaTips:Delta mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetAH Series, AS Series, AX-3 Series, DVP Series (built-in Ethernet)
MODBUS RTUSerial portAH Series, AS Series, AX-3 Series, DVP Series
XinJETips:XinJE mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetCCSD Series, XA Series, XS Series, XG Series, XL Series
MODBUS RTUSerial portCCSD Series, XA Series, XS Series, XG Series, XL Series, XC Series, XD Series
MegMeetTips:MegMeet mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
MODBUS RTUSerial portMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
YaskawaTips:Yaskawa mainly uses the MEMOBUS protocol for communication (supports S7) .
MemobusEthernetGL120/130 Series, GL60 Series, MP3000 Series, MP2300 Series, Z1000 Series
FatekTips:Fatek mainly uses the Fatek protocol for communication.
FatekSerial portFBs Series
VigorTips:Vigor mainly uses the VS private protocol for communication.
VSSerial portVS Series
FujiTips:Fuji mainly uses the SPH/SPB protocol for communications.
SPHEthernetSPH Series
SPBSerial portSPB Series

 

Specification

ModelEG8200Pro
Core ConfigurationCPU8 cores A55@1.8G
Memory2G
eMMC16G
StorageSD card128G max (Optional)
4GModuleQuectel-CAT4
Frequency BandLTE-FDD: B1/B3/B5/B8
LTE-TDD: B34/B38/B39/B40/B41
WCDMA: B1/B5/B8
GSM: 900/1800MHz
Transmit PowerLTE-TDD: Class 3 (23 dBm ±2 dB)
LTE-FDD: Class 3 (23 dBm ±2 dB)
WCDMA: Class 3 (24 dBm +1/-3 dB)
PCS1900 8-PSK: Class E2 (26 dBm ±3 dB)
DCS1800 8-PSK: Class E2 (26 dBm ±3 dB)
EGSM900 8-PSK: Class E2 (27 dBm ±3 dB)
GSM850 8-PSK: Class E2 (27 dBm ±3 dB)
PCS1900: Class 1 (30 dBm ±2 dB)
DCS1800: Class 1 (30 dBm ±2 dB)
EGSM900: Class 4 (33 dBm ±2 dB)
GSM850: Class 4 (33 dBm ±2 dB)
Bandwidth (The maximum rate is theoretical)LTE-FDD: Max 150Mbps(DL)/Max 50Mbps(UL)
LTE-TDD: Max 130Mbps(DL)/Max 30Mbps(UL)
5G (Optional)ModuleQuectel-5G
Frequency Band5G NR SA: n1/n28/n41/n77/n78/n79
5G NR NSA: n41/n78/n79
LTE-FDD: B1/B2/B3/B5/B7/B8/B20/B28
LTE-TDD: B34/B38/B39/B40/B41
WCDMA: B1/B2/B5/B8
Transmit Power5G NR n41/n78/n79 HPUE: Class 2 (26 dBm +2/-3 dB)
5G NR n77/n78/n79: Class 3 (23 dBm +2/-3 dB)
5G NR n28: Class 3 (23 dBm +2/-2.5 dB)
5G NR n1/n41: Class 3 (23 dBm +2 dB)
LTE B41 HPUE: Class 2 (26 dBm +2 dB)
LTE: Class 3 (23 dBm +2 dB)
WCDMA: Class 3 (23 dBm ±2 dB)
Bandwidth (The maximum rate is theoretical)NSA: 2.2 Gbps(Downlink Rate)/575 Mbps(Uplink Rate)
SA: 2 Gbps(Downlink Rate)/1 Gbps(Uplink Rate)
LTE: 600 Mbps(Downlink Rate)/150 Mbps(Uplink Rate)
WiFiWireless StandardsIEEE 802.11b/g/n/ac
Wireless Frequency2.4~2.4835GHz & 5.15~5.85GHz
WiFi ModeAP+Station
Theoretical Rate433Mbps
Optimal Communication Distance10m
Number of AP Mode Links20
EthernetWAN1 × 10M/100M/1000M Self-Adaptive
LAN1 × 10M/100M/1000M Self-Adaptive
RS232Number of Interfaces1 Way
TerminalsRX, TX, GND
Baud Rate2400~921600bps
Data Bits7, 8
Stop Bits1, 2
Check DigitNONE (No Check Digit)
EVEN (Even Check)
ODD (Odd Check)
ProtectionAnti-static, Anti-surge
RS485Number of Interfaces3-way
TerminalsA, B
Baud Rate2400~921600bps
Data Bits7, 8
Stop Bits1, 2
Check DigitNONE (No Check Digit)
EVEN (Even Check)
ODD (Odd Check)
ProtectionAnti-static, Anti-surge
DONumber of Interfaces2-way
Terminals(NO, COM) ×2
AC Capacity250V 5A
DC Capacity30V 5A
Mechanical Durability10^6
Appliance Durability10^5
DINumber of Interfaces2-way
TerminalsDI*2, COM*2
Detection RangeDry Contact/NPN/PNP: Support 12V/24V
Impedance2K
ProtectionOptocoupler Isolation, Anti-static, Anti-surge
AONumber of Interfaces2-way
TerminalsAO*2, COM*2
Output Range4~20mA
Sample Rate12-bit Ad
Precision1%
ProtectionAnti-static, Anti-surge
AINumber of Interfaces2-way
TerminalsAI*2, COM*2
Detection Range4~20mA
Sample Rate12-bit Ad
Precision1%
Impedance250Ω
ProtectionAnti-static, Anti-surge
USBNumber of Interfaces2 × USB2.0
HDMINumber of Interfaces1 way
RTCLocal Clock
Electrical ParametersAuthenticationCE
Adapter12V/2A
Operating Voltage9~36V
Operating Current500mA/12V
Environmental ParametersOperating Temperature-40~80℃
Storage Temperature-40~80℃
Operating Humidity0~95%RH (No Condensation)
Store Humidity0~95%RH (No Condensation)
Mechanical ParametersSize232×150×53mm
Housing MaterialAluminum Profiles
InstallationScrew-fastened
Heat DissipationPassive Cooling
REST ButtonPress and Hold for 10s to Reset
EMCElectrostatic DischargeAir Discharge level3 ±8KV
Contact Discharge level2 ±4KV
Surgelevel2±1KV
Burst (EFT)level2±1KV
Software FeaturesRemote O&M
Remote Management
Remote Upgrades
Virtual Network Port
Virtual serial port
Time Series Databases
Visual Programming
PLC Protocols
Industry ProtocolsCJ188 / DLT645 / HJ212 / Modbus / OPC UA / BACnet, etc
Web Configuration
Network ProtocolsMQTT / HTTP / TCP / UDP / WEB SOCKET / Alibaba Cloud IoT Platform / OneNET, etc
SystemSystemLinux

4G bands

*You may contact customer service to select the corresponding module for replacement.

Module TypeFrequency Bands
EC200A-CNLTE FDD: B1/B3/B5/B8
LTE TDD: B34/B38/B39/B40/B41
UMTS WCDMA: B1/B5/B8
EC200A-EULTE FDD: B1/B3/B5/B7/B8/B20/B28
LTE TDD: B38/B40/B41
UMTS WCDMA: B1/B5/B8
EC200A-AULTE FDD: B1/B2/B3/B4/B5/B7/B8/B28/B66
LTE TDD: B40
UMTS WCDMA: B1/B2/B4/B5/B8

Download