EG8200Mini-104: Modbus To IEC 104 Gateway For Substation And SCADA Systems - IOTROUTER
Search

EG8200Mini-104: Modbus to IEC 104 Gateway for Substation and SCADA Systems

Reliable IEC 104 Protocol Converter for Power Systems

EG8200Mini-104 connects Modbus devices to IEC 104 SCADA systems with millisecond-level data acquisition for power and substation applications.

Video Video





Industry Protocols
CJ188/DLT645/HJ212/1EC104/Modbus/OPC UA/BACnet
Network Protocols
MQTT/ HTTP /TCP/ UDP /WEBSOCKET

INTERFACE

2*RS485, 1*RS232, 1*WAN, 1*LAN
COMMUNICATION
LTE 4G, RJ45, WiFi

Categories: , Buy on Alibaba

Description

EG8200Mini-104 is an IEC 104 Gateway (IEC 60870-5-104 gateway ) designed for power automation and substation communication. It enables seamless conversion of Modbus RTU/TCP and PLC data into IEC 104 for integration with SCADA and dispatch systems.

It supports flexible master-slave configuration for bidirectional data exchange, as well as multi-device networking to interconnect multiple IEC 104 devices within a LAN. With support for multiple industrial protocols, remote management, and stable network connectivity, it ensures reliable data acquisition and transmission in energy and utility environments.

Key Features

iiotGateway_keyfeatures_01

IEC 104 Server/Client

Standard Server/Client modes for stable SCADA

iiotGateway_keyfeatures_02

Low-Code Development

Visual programming with built-in Node-RED

iiotGateway_keyfeatures_03

Remote Virtual LAN

Virtual LAN for remote PLC access and program upload/download

iiotGateway_keyfeatures_04

Multi-Protocol

Seamless communication across industrial protocols

iiotGateway_keyfeatures_05

Edge Intelligence

Local data analysis and logic execution at the edge

iiotGateway_keyfeatures_06

Remote Management

Remote configuration, debugging, and program updates

iiotGateway_keyfeatures_07

Reliable Connectivity

4G / Ethernet / Wi-Fi with auto failover

iiotGateway_keyfeatures_08

Industrial-Grade

Operates from −40°C to 85°C with 9–36V wide voltage input

* Support OEM/ODM, contact customer service for details.


EG8200Mini-104 Modbus RTU TCP To IEC104 Edge Gateway EG8200Mini-104 Modbus RTU TCP To IEC104 Edge Gateway


EG Series Products

All gateways in the EG series share a highly consistent operating method. Differences between models are mainly reflected in hardware interfaces, and the corresponding variations are limited to the presence or absence of certain functional nodes.

EG Series8200 Pro82008200 Mini8200 Lite82082000
Key FeatureHigh PerformanceMulti-interfaceStandard VersionDIN-rail VersionCNC VersionIEC104 VersionLow Cost8 Serial PortsLoRa Gateway
ProcessorOcta-core A55 @1.8GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHzA7 @1.2GHzDual-core A7 @1.2GHzDual-core A7 @1.2GHz
Memory2GB512MB512MB512MB512MB512MB256MB512MB512MB
eMMC16GB4GB4GB4GB4GB4GB4GB4GB4GB
SD CardMax 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)Max 128GB (optional)×Max 128GB (optional)Max 128GB (optional)
4G×√ (optional)√ (optional)
5G√ (optional)××××××××
HDMI××××××××
Ethernet Ports1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN/LAN1×WAN/LAN1×WAN/LAN
LoRa××××××××
Wi-FiDual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6Dual-band Wi-Fi 6×××
GPS××××××××
USB2×USB 2.01×USB 2.0×××××××
RTC×
RS485322222281
RS232111111×××
CAN×2×××××××
DO22×××××8×
DI22×××××××
AO2××××××××
AI2××××××××
Operating Voltage9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V
Operating Current500mA@12V280mA/12V150mA/12V150mA/12V150mA/12V150mA/12V60mA/12V170mA/12V180mA/12V
CertificationCECECECECECECECECE
Operating Temperature-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-20 ~ 85°C-40 ~ 85°C-40 ~ 85°C
Remote O&M
Remote Management
Remote Upgrade
Virtual Network Interface
Virtual Serial Port
Local Database×
Visual Programming
PLC Protocol×××
CNC Protocol××××××××
IEC 60870-5-104××××××××
Web Configuration××××××××
Industry ProtocolsCJ188/DLT645/HJ212/Modbus/OPC UA*/BACnet*/etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical
Network ProtocolsMQTT / HTTP / TCP / UDP / WebSocket / Alibaba Cloud IoT Platform / OneNET / etc.IdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdenticalIdentical

Quick Access to EG Series Products →


Main Functions

EG8200Mini-104 Modbus to IEC 104 Gateway01

Wide PLC Compatibility

– Millisecond-Level Data Acquisition – 

Supports communication with major PLC brands, including Siemens, Mitsubishi (MELSEC), Omron, Allen-Bradley, Beckhoff, Inovance, Keyence, Panasonic, Delta, and others, enabling rapid PLC data acquisition for edge applications. For a detailed list of supported PLC protocol models, please contact customer service.

Multi-Protocol Support

– Third-Party Platform Integration –

Supports standard industrial protocols, including Modbus, MQTT, OPC UA/DA, HJ212, and IEC 60870-5-104, enabling seamless integration with SCADA systems, cloud platforms, and other third-party applications. For non-standard protocols, custom parsing and logic can be implemented using JavaScript (JS).

EG8200Mini-104 Modbus to IEC 104 Gateway02
EG8200Mini-104 Modbus to IEC 104 Gateway05

Remote Management

The EG8200 series remote management software enables remote configuration, debugging, diagnostics, and program updates for on-site devices.

Remote Virtual LAN

– PLC Remote Upload & Download –

With Virtual Ethernet and Virtual Serial Port, engineers can remotely access PLCs, HMIs, and serial devices for programming, maintenance, and debugging as if they were on the same local network.

EG8200Mini-104 Modbus to IEC 104 Gateway07
EG8200Mini-104 Modbus to IEC 104 Gateway08

Drag & Drop Programming

– Low-code visual programming –

Using Node-RED visual programming, the EG8200Mini-104 gateway allows users to build automation workflows through drag-and-drop configuration. It supports integration with sensors and third-party platforms via protocols such as MQTT and JSON.



FAQ

Q1: What network options does the EG8200Mini-104 edge IEC 104 Gateway support? How can I use it in a substation without Ethernet?

A: EG8200Mini-104 IEC 104 Gateway offers very flexible networking options, fitting a variety of industrial site scenarios:

    • Wired (RJ45): Connect via the Gigabit WAN port or 100Mbps LAN port to your local network.

    • Wi-Fi: Supports dual-band Wi-Fi (2.4GHz & 5GHz) as a client to connect to existing wireless networks.

    • Cellular (4G LTE): Built-in 4G Cat.1 module—just insert a SIM card, and your gateway can send data over the mobile network.

So even in older substations with no network cables, you can still use 4G to reliably send data back to the control center.

Q2: How do I use the EG8200Mini-104 IEC 104 Gateway to read substation digital and analog data? Is it complicated?

A: Configuration is straightforward using the visual Node-RED tool—no coding required. Here’s the core workflow:

1. Network setup: Ensure the gateway is on the same network as your substation devices (e.g., protection relays). You can adjust the LAN IP via the management interface.

2. Add nodes: In Node-RED, drag an IEC104 Client node from the left palette into your workflow.

3. Configure connections and points:

      • In the node settings, enter the remote 104 slave’s IP address and port (default is 2404).

      • Digital inputs (DI/status points): Go to the “Digital” tab, add the points using the slave’s point addresses (like 1, 2), and assign names.

      • Analog inputs (AI/measurements): Go to the “Analog” tab, add the points with the corresponding addresses (like 16385, 16386) and names.

    1. 4. Deploy & verify: Once deployed, the gateway will automatically read data at the configured intervals. You can monitor real-time values in the debug panel.

Product Size and Interfaces

EG8200Mini-104 Modbus to IEC 104 Gateway09


Packing List

EG8200Mini-104 Modbus to IEC 104 Gateway10


industrial edge gateway

Datasheet

HardwareCPU2*Cortex-A7@1.2GHz
Memory512M
EMMC4G (MLC)
SD cardUp to 128G (influxdb pre-installed)
RTCReal Time Clock
WirelessLTE Cat1
WAN1*10M/100M/1000M Self-Adaptive
LAN1*10M/100M Self-Adaptive
WiFiAP+Station
RS4852* RS485
RS2321* RS232
LEDCustomizable
Electrical ParametersOperating Voltage9~36V
Operating Current150mA/12V
Adapter12V/2A
Power ProtectionAnti-static, anti-surge, anti-reverse
CertificationCE/ROHS/FCC
Environmental ParametersOperating Temperature-40~85℃
Storage Temperature-40~85℃
Operating Humidity0-95%RH(No Condensation)
Cooling MethodHeat sink/Dissipation silicone
Mechanical ParametersSize115*90*35mm/125*95*32mm
Weight<1kg
MaterialZinc Alloy
Software ParametersOpsSupport remote configuration/upgrade/management
VPNSupport intranet penetration/PLC remote upload&download/virtual serial port
Edge ComputingSupport visual programming, zero-code development, drag-and-drop programming, secondary development, compilation-free
Data StorageSupport cache queues/file read&write/disconnected transfer/ influxdb
Industrial AgreementSupport multiple industrial protocols
Network ProtocolMQTT/HTTP/TCP/UDP

PLC Protocols

EG8000 Series Edge Computing Gateway PLC Protocols

The gateway is categorized according to the hierarchical structure of brand->protocol->model, and representative PLC models are selected for testing in each category. The rest of the supported models are from the official documents.
Note: The gateway supports the standard MOBUDS RTU/TCP protocol, which is supported by all mainstream PLCs. (For example, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

BrandProtocolInterfacePLC Model
SIEMENSTips:Siemens in the sale of the series all support S7 protocol communication, it is recommended to use the S7 protocol communication.
S7EthernetS7-S200smart, S7-S200 Series, S7-S300 Series, S7-S400 Series, S7-S1200 Series, S7-S1500 Series
PPISerial portS7-200 Series
MELSECTips:Mitsubishi mainly uses MC protocol for communication, FX5 Series, FX3 Series, Q Series, etc. are tested.
EtherNet/IPEthernetFX5-ENET/IP Series, RJ71EIP91 Series, QJ71EIP71 Series
MC-1E/MC-3EEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series, QnUCPU Series, FX3 Series
MODBUS TCPEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series
MC-3CSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series
MODBUS RTUSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series, FX3 Series
FxLinksSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
FxSerialSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
OMRONTips:Omron mainly uses the Fins protocol for communication.
EtherNet/IPEthernetNX7 Series, NX1 Series, NX1P Series, NJ Series, CJ1W-EIP21
FinsEthernetCP Series, CS Series, CJ Series, CV Series
HostLinkSerial portCP Series, CS Series, CJ Series, CV Series, C Series
LSisTips:LS mainly uses FEnet/Cnet protocol for communication.
XGB FEnetEthernetXGB Series (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetXGT Series (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetSerial portXGB Series (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetSerial portXGT Series (XGL-CH2A, XGL-C21A, XGL-C41A)

BrandProtocolInterfacePLC Model
AllenBrandlyTips:Rockwell mainly uses CIP, DF1 protocol for communication.
EtherNet/IPEthernetControlLogix Series, CompactLogix Series, Micro800 Series (820, 850, 870)
DF1Serial portControlLogix Series, CompactLogix Series (5069-SERIAL module) , Micro800 Series (820, 830, 850, 870)
SLC Series (500, 5/03, 5/04, 5/05) , Micro-Logix Series (1000, 1100, 1200, 1500)
BeckhoffTips:Beckhoff mainly uses the ADS protocol for communication.
ADSEthernetCX Series, TwinCAT2, TwinCAT3
InovanceTips:Inovance mainly adopts MODBUS protocol for communication.
MODBUS TCPEthernetAC Series, AM Series, H5U Series, H3U Series
MODBUS RTUSerial portAC Series, AM Series, H5U Series, H3U Series, H1U Series
KeyenceTips:Keyence mainly uses the KV protocol for communication.
MC-3EEthernetKV-8000 Series, KV-7000 Series, KV-5500 Series, KV-5000 Series
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A and other Ethernet units
KVEthernet
KVSerial portKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicTips:Panasonic mainly uses the Mewtocol protocol for communication.
MC-3EEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolSerial portFP7 Series, FP0H Series, FP-XH Series, FP-X0 Series, FP0R Series
DeltaTips:Delta mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetAH Series, AS Series, AX-3 Series, DVP Series (built-in Ethernet)
MODBUS RTUSerial portAH Series, AS Series, AX-3 Series, DVP Series
XinJETips:XinJE mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetCCSD Series, XA Series, XS Series, XG Series, XL Series
MODBUS RTUSerial portCCSD Series, XA Series, XS Series, XG Series, XL Series, XC Series, XD Series
MegMeetTips:MegMeet mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
MODBUS RTUSerial portMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
YaskawaTips:Yaskawa mainly uses the MEMOBUS protocol for communication (supports S7) .
MemobusEthernetGL120/130 Series, GL60 Series, MP3000 Series, MP2300 Series, Z1000 Series
FatekTips:Fatek mainly uses the Fatek protocol for communication.
FatekSerial portFBs Series
VigorTips:Vigor mainly uses the VS private protocol for communication.
VSSerial portVS Series
FujiTips:Fuji mainly uses the SPH/SPB protocol for communications.
SPHEthernetSPH Series
SPBSerial portSPB Series

4G bands

*You may contact customer service to select the corresponding module for replacement.
 
Module TyleFrequency Bands
EC800K-CNLTE FDD: B1/B3/B5/B8
LTE TDD: B34/B38/B39/B40/B41
EG800K-EULTE FDD: B1/B3/B5/B7/B8/B20/B28
EG800K-LALTE FDD: B2/B3/B4/B5/B7/B8/B28/B66

Download

Apply For Product Samples