Schwebe-Animation

4IO network controller

Verwandte Videos

Kontakt

WhatsApp / Telefon

Unlike traditional solutions, signal transmission via the network no longer requires PLC or PC control. The hardware of the network controller IO controller can automatically map all physical switch signals without the need for ladder diagram or C language programming. With a network IO controller, input signals can be easily transmitted to the other end of the network via Ethernet, eliminating the need for programming or a separate controller for control.

Zongheng Intelligent Control 4IO network controller can transmit switching signals through the IP network, which can completely replace the existing cable-based signal transmission solutions. This product has 4DI, 4DO and 4AI and an Ethernet port. Using 4IO network controllers in pairs can transmit 4 sets of input and output signals to a PLC or DCS control system through the network.

Eigenschaften

● 4 digital inputs, 4 digital outputs, and 4 analog inputs;

● DO follows AI/DI remotely, and logic can be configured freely;

●Transmit physical signals through Ethernet;

● Point-to-point/point-to-multipoint networking communication;

● Modbus TCP/RTU adaptive;

● I/O is completely isolated from the system;

● The power supply has good overcurrent, overvoltage, and anti-reverse connection protection functions;

● Rich indicator lights, comprehensive view of status, timely troubleshooting;

● Software and hardware dual watchdogs ensure stable operation of the equipment.

Technical Parameters

Netzwerk-Parameter
Netzwerktyp Ethernet
Anzahl der Netzwerkanschlüsse (10/100M) LAN*1
Typ des Netzwerkanschlusses Ethernet-Signal RJ45
Schutz durch elektromagnetische Isolierung 15KV electromagnetic isolation
Cross-connect automatic switching
Externer Netztransformator unnötig
serielle Schnittstelle
Anzahl der Häfen RS485*1
Standard RS485: 2-polige Klemmleiste (A, B)
Baudrate 600~921600bps
Datenbits 8,9
Stoppbit 0.5 , 1 , 1.5 , 2
Prüfziffer NONE (kein Paritätsbit) EVEN (gerade Parität) ODD (ungerade Parität)
DO
Anzahl der Schnittstellen 4 relay outputs
Standard (NO, NC, COM)*4
AC 250V 10A
DC 30V 10A
Mechanische Haltbarkeit 10^7
Appliance durability 10^5
DI (trockener Knoten)
Anzahl der Schnittstellen 6
Standard DI*6, COM*1
DI (nasser Knoten)
Anzahl der Schnittstellen 6
Standard DI*6, COM*1
examination range 5~50V->Hoch 0~2V->Niedrig
PI
Anzahl der Schnittstellen 2
Standard PI*2, COM*1
examination range 10000Hz
AI
Anzahl der Schnittstellen 4
Standard AI*4, COM*2
examination range 4~20mA
Stromzufuhr
Betriebsspannung 9~36V
Working current

200mA(aver)/340mA(max)@9V

50mA(aver)/85mA(max)@36V

examination range 10000Hz
EMC level
ESD IEC61000-4-2, Stufe 4
Überspannung

IEC61000-4-2, Stufe 3

Gruppenimpuls IEC61000-4-2, Stufe 3
Mechanical structure
Größe der Ausrüstung 159.5*115.5*27.6mm(L*W*H)
shell haben

Kontakt