EG8200Mini-104: Modbus To IEC 104 Gateway For Substation And SCADA Systems - IOTROUTER
Schwebe-Animation

EG8200Mini-104: Modbus to IEC 104 Gateway for Substation and SCADA Systems

Reliable IEC 104 Protocol Converter for Power Systems

EG8200Mini-104 connects Modbus devices to IEC 104 SCADA systems with millisecond-level data acquisition for power and substation applications.

Video Video





Industrie-Protokolle
CJ188/DLT645/HJ212/1EC104/Modbus/OPC UA/BACnet
Netzwerk-Protokolle
MQTT/ HTTP /TCP/ UDP /WEBSOCKET

INTERFACE

2*RS485, 1*RS232, 1*WAN, 1*LAN
KOMMUNIKATION
LTE 4G, RJ45, WiFi

Kategorien: , Auf Alibaba kaufen

Beschreibung

EG8200Mini-104 is a DIN-rail IEC 104 Gateway (IEC 60870-5-104 gateway ) designed for power automation and substation communication. It enables seamless conversion of Modbus RTU/TCP and PLC data into IEC 104 for integration with SCADA and dispatch systems.

It supports flexible master-slave configuration for bidirectional data exchange, as well as multi-device networking to interconnect multiple IEC 104 devices within a LAN. With support for multiple industrial protocols, remote management, and stable network connectivity, it ensures reliable data acquisition and transmission in energy and utility environments.

Wesentliche Merkmale

iiotGateway_Schlüsselmerkmale_01

IEC 104 Server/Client

Standard Server/Client modes for stable SCADA

iiotGateway_Schlüsselmerkmale_02

Low-Code-Entwicklung

Visuelle Programmierung mit eingebautem Node-RED

iiotGateway_Schlüsselmerkmale_03

Entferntes virtuelles LAN

Virtual LAN for remote PLC access and program upload/download

iiotGateway_Schlüsselmerkmale_04

Multi-Protokoll

Nahtlose Kommunikation über Industrieprotokolle hinweg

iiotGateway_Schlüsselmerkmale_05

Edge Intelligence

Lokale Datenanalyse und logische Ausführung am Rand

iiotGateway_Schlüsselmerkmale_06

Fernverwaltung

Fernkonfiguration, Debugging und Programmaktualisierung

iiotGateway_Schlüsselmerkmale_07

Zuverlässige Konnektivität

4G / Ethernet / Wi-Fi mit automatischer Ausfallsicherung

iiotGateway_Schlüsselmerkmale_08

Industrietauglich

Betrieb von -40°C bis 85°C mit 9-36V Weitspannungseingang

* unterstützen OEM/ODM, Wenden Sie sich an den Kundendienst, um Einzelheiten zu erfahren.


EG8200Mini-104 Modbus RTU TCP zu IEC104 Edge Gateway EG8200Mini-104 Modbus RTU TCP zu IEC104 Edge Gateway


EG-Serie Produkte

Alle Gateways der EG-Serie verfügen über eine sehr einheitliche Funktionsweise. Die Unterschiede zwischen den Modellen spiegeln sich hauptsächlich in den Hardwareschnittstellen wider, und die entsprechenden Abweichungen beschränken sich auf das Vorhandensein oder Fehlen bestimmter Funktionsknoten.

EG-Reihe8200 Profi82008200 Mini8200 Leicht82082000
HauptmerkmalHohe LeistungMulti-InterfaceStandardversionDIN-Schienen VersionCNC-AusführungIEC104 FassungNiedrige Kosten8 serielle SchnittstellenLoRa-Gateway
ProzessorOcta-Core A55 @1.8GHzDual-Core A7 @1,2GHzDual-Core A7 @1,2GHzDual-Core A7 @1,2GHzDual-Core A7 @1,2GHzDual-Core A7 @1,2GHzA7 @1.2GHzDual-Core A7 @1,2GHzDual-Core A7 @1,2GHz
Speicher2GB512MB512MB512MB512MB512MB256MB512MB512MB
eMMC16GB4GB4GB4GB4GB4GB4GB4GB4GB
SD-KarteMaximal 128 GB (optional)Maximal 128 GB (optional)Maximal 128 GB (optional)Maximal 128 GB (optional)Maximal 128 GB (optional)Maximal 128 GB (optional)×Maximal 128 GB (optional)Maximal 128 GB (optional)
4G×√ (fakultativ)√ (fakultativ)
5G√ (fakultativ)××××××××
HDMI××××××××
Ethernet-Ports1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN + 1×LAN1×WAN/LAN1×WAN/LAN1×WAN/LAN
LoRa××××××××
Wi-FiDualband-Wi-Fi 6Dualband-Wi-Fi 6Dualband-Wi-Fi 6Dualband-Wi-Fi 6Dualband-Wi-Fi 6Dualband-Wi-Fi 6×××
GPS××××××××
USB2×USB 2.01×USB 2.0×××××××
RTC×
RS485322222281
RS232111111×××
CAN×2×××××××
DO22×××××8×
DI22×××××××
AO2××××××××
AI2××××××××
Betriebsspannung9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V9~36V
Betriebsstrom500mA@12V280mA/12V150mA/12V150mA/12V150mA/12V150mA/12V60mA/12V170mA/12V180mA/12V
ZertifizierungCECECECECECECECECE
Betriebstemperatur-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-40 ~ 85°C-20 ~ 85°C-40 ~ 85°C-40 ~ 85°C
Ferngesteuertes O&M
Fernverwaltung
Fern-Upgrade
Virtuelle Netzwerkschnittstelle
Virtuelle serielle Schnittstelle
Lokale Datenbank×
Visuelle Programmierung
PLC-Protokoll×××
CNC-Protokoll××××××××
IEC 60870-5-104××××××××
Web-Konfiguration××××××××
Industrie-ProtokolleCJ188/DLT645/HJ212/Modbus/OPC UA*/BACnet*/etc.IdentischIdentischIdentischIdentischIdentischIdentischIdentischIdentisch
Netzwerk-ProtokolleMQTT / HTTP / TCP / UDP / WebSocket / Alibaba Cloud IoT Platform / OneNET / etc.IdentischIdentischIdentischIdentischIdentischIdentischIdentischIdentisch

Schnellzugriff auf Produkte der EG-Serie →


Hauptfunktionen

EG8200Mini-104 Modbus to IEC 104 Gateway01

Breite PLC-Kompatibilität

- Datenerfassung im Millisekundenbereich - 

Supports communication with major PLC brands, including Siemens, Mitsubishi (MELSEC), Omron, Allen-Bradley, Beckhoff, Inovance, Keyence, Panasonic, Delta, and others, enabling rapid PLC data acquisition for edge applications. For a detailed list of supported PLC protocol models, please get in touch with customer service.

Multi-Protokoll-Unterstützung

- Integration von Drittanbieter-Plattformen -

Supports standard industrial protocols, including Modbus, MQTT, OPC UA/DA, HJ212, and IEC 60870-5-104, enabling seamless integration with SCADA systems, cloud platforms, and other third-party applications. For non-standard protocols, custom parsing and logic can be implemented using JavaScript (JS).

EG8200Mini-104 Modbus to IEC 104 Gateway02
EG8200Mini-104 Modbus to IEC 104 Gateway05

Fernverwaltung

The EG8200 series remote management software enables remote configuration, debugging, diagnostics, and program updates for on-site devices.


Entfernter virtueller LAN/ serieller Anschluss

- PLC Remote Upload & Download -

Mit Virtual Ethernet und Virtual Serial Port können Ingenieure aus der Ferne auf SPS, HMI und serielle Geräte zugreifen, um sie zu programmieren, zu warten und zu debuggen, als ob sie sich im selben lokalen Netzwerk befänden.

EG8200Mini-104 Modbus to IEC 104 Gateway07
EG8200Mini-104 Modbus to IEC 104 Gateway08

Drag & Drop Programmierung

- Visuelle Programmierung mit niedrigem Code -

Using Node-RED visual programming, the EG8200Mini-104 gateway allows users to build automation workflows through drag-and-drop configuration. It supports integration with sensors and third-party platforms via protocols such as MQTT and JSON.



FAQ

Q1: What network options does the EG8200Mini-104 edge IEC 104 Gateway support? How can I use it in a substation without Ethernet?

A1: EG8200Mini-104 IEC 104 Gateway offers very flexible networking options, fitting a variety of industrial site scenarios:

    • Wired (RJ45): Connect via the Gigabit WAN port or 100Mbps LAN port to your local network.

    • Wi-Fi: Supports dual-band Wi-Fi (2.4GHz & 5GHz) as a client to connect to existing wireless networks.

    • Cellular (4G LTE): Built-in 4G Cat.1 module—just insert a SIM card, and your gateway can send data over the mobile network.

So even in older substations with no network cables, you can still use 4G to reliably send data back to the control center.

Q2: How do I use the EG8200Mini-104 IEC 104 Gateway to read substation digital and analog data? Is it complicated?

A2: Configuration is straightforward using the visual Node-RED tool—no coding required. Here’s the core workflow:

1. Network setup: Ensure the gateway is on the same network as your substation devices (e.g., protection relays). You can adjust the LAN IP via the management interface.

2. Add nodes: In Node-RED, drag an IEC104 Client node from the left palette into your workflow.

3. Configure connections and points:

      • In the node settings, enter the remote 104 slave’s IP address and port (default is 2404).

      • Digital inputs (DI/status points): Go to the “Digital” tab, add the points using the slave’s point addresses (like 1, 2), and assign names.

      • Analog inputs (AI/measurements): Go to the “Analog” tab, add the points with the corresponding addresses (like 16385, 16386) and names.

    1. 4. Deploy & verify: Once deployed, the gateway will automatically read data at the configured intervals. You can monitor real-time values in the debug panel.

Q3: How does the EG8200Mini-104 ensure power data security?

A3: The gateway employs a multi-layered security system compliant with industry standards:

    • Standard Protocol: Strictly adheres to IEC 60870-5-104 to ensure reliable data transmission.

    • Network Isolation: Supports VPNs and dedicated LANs to block external cyber threats.

    • Access Control: All commands are mapped to pre-defined point tables to prevent unauthorized operations.

    • Safe Execution: Implements the “Select-before-Execute” mechanism to prevent accidental or malicious control commands.

This 4-layer approach ensures the stability and safety of your power monitoring system.


Produktgröße und Schnittstellen

EG8200Mini 104


Packliste

104_1_11zon


Industrie-Edge-Gateway

Datenblatt

HardwareCPU2*Cortex-A7@1.2GHz
Speicher512M
EMMC4G (MLC)
SD-KarteBis zu 128 GB (influxdb ist vorinstalliert)
RTCEchtzeituhr
DrahtlosLTE Kat1
WAN1*10M/100M/1000M Selbstanpassung
LAN1 × 10/100 M Selbstanpassend
WiFiAP+Station
RS4852* RS485
RS2321* RS232
LEDAnpassbar
Elektrische ParameterBetriebsspannung9~36V
Betriebsstrom150mA/12V
Adapter12V/2A
Schutz der StromversorgungAnti-Statik, Anti-Surge, Anti-Reverse
ZertifizierungCE/ROHS/FCC
UmweltparameterBetriebstemperatur-40~85℃
Lagertemperatur-40~85℃
Luftfeuchtigkeit im Betrieb0-95%RH(ohne Kondensation)
Methode der KühlungKühlkörper/Ableitungssilikon
Mechanische ParameterGröße115*90*35mm/125*95*32mm
Gewicht<1kg
MaterialZink-Legierung
Software-ParameterOpsUnterstützung von Fernkonfiguration/-aktualisierung/-verwaltung
VPNUnterstützung der Intranet-Penetration/PLC-Fern-Upload&Download/virtueller serieller Anschluss
Edge ComputingUnterstützung für visuelle Programmierung, Zero-Code-Entwicklung, Drag-and-Drop-Programmierung, sekundäre Entwicklung, kompilierungsfrei
DatenspeicherungUnterstützung von Cache-Warteschlangen/Datei lesen und schreiben/getrennte Übertragung/ influxdb
IndustrieabkommenUnterstützung mehrerer Industrieprotokolle
Netzwerk-ProtokollMQTT/HTTP/TCP/UDP

PLC-Protokolle

EG8000 Serie Edge Computing Gateway PLC Protokolle

Das Gateway ist entsprechend der hierarchischen Struktur von Marke->Protokoll->Modell kategorisiert, und in jeder Kategorie werden repräsentative SPS-Modelle zum Testen ausgewählt. Der Rest der unterstützten Modelle stammt aus den offiziellen Dokumenten.
Hinweis: Das Gateway unterstützt das Standard-MOBUDS-RTU/TCP-Protokoll, das von allen gängigen SPSen unterstützt wird. (z.B. HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

MarkeProtokollSchnittstellePLC-Modell
SIEMENSTipps:Siemens in den Verkauf der Serie unterstützen alle S7-Protokoll-Kommunikation, ist es empfehlenswert, die S7-Protokoll-Kommunikation zu verwenden.
S7EthernetS7-S200smart, S7-S200 Serie, S7-S300 Serie, S7-S400 Serie, S7-S1200 Serie, S7-S1500 Serie
PPISerieller AnschlussBaureihe S7-200
MELSECTipps:Mitsubishi verwendet hauptsächlich das MC-Protokoll für die Kommunikation, die FX5-Serie, FX3-Serie, Q-Serie usw. werden getestet.
EtherNet/IPEthernetFX5-ENET/IP-Serie, RJ71EIP91-Serie, QJ71EIP71-Serie
MC-1E/MC-3EEthernetFX5-Serie, RJ71EN71-Serie, RnENCPU-Serie, LJ71E71-Serie, QJ71E71-Serie, QnUCPU-Serie, FX3-Serie
MODBUS TCPEthernetSerie FX5, Serie RJ71EN71, Serie RnENCPU, Serie LJ71E71, Serie QJ71E71
MC-3CSerieller AnschlussSerie FX5, Serie RJ71C24, Serie LJ71C24, Serie QJ71C24
MODBUS RTUSerieller AnschlussSerie FX5, Serie RJ71C24, Serie LJ71C24, Serie QJ71C24, Serie FX3
FxLinksSerieller AnschlussSerie FX3, Serie FX2, Serie FX1, Serie FX0
FxSerialSerieller AnschlussSerie FX3, Serie FX2, Serie FX1, Serie FX0
OMRONTipps:Omron verwendet für die Kommunikation hauptsächlich das Fins-Protokoll.
EtherNet/IPEthernetBaureihe NX7, Baureihe NX1, Baureihe NX1P, Baureihe NJ, CJ1W-EIP21
FlossenEthernetCP-Serie, CS-Serie, CJ-Serie, CV-Serie
HostLinkSerieller AnschlussCP-Serie, CS-Serie, CJ-Serie, CV-Serie, C-Serie
LS istTipps:LS verwendet hauptsächlich das FEnet/Cnet-Protokoll für die Kommunikation.
XGB FEnetEthernetXGB-Serie (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetXGT-Serie (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetSerieller AnschlussXGB-Serie (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetSerieller AnschlussXGT-Serie (XGL-CH2A, XGL-C21A, XGL-C41A)

MarkeProtokollSchnittstellePLC-Modell
AllenBrandlyTipps:Rockwell verwendet für die Kommunikation hauptsächlich das CIP- und DF1-Protokoll.
EtherNet/IPEthernetControlLogix-Serie, CompactLogix-Serie, Micro800-Serie (820, 850, 870)
DF1Serieller AnschlussControlLogix-Serie, CompactLogix-Serie (5069-SERIAL-Modul), Micro800-Serie (820, 830, 850, 870)
SLC-Serie (500, 5/03, 5/04, 5/05) , Micro-Logix-Serie (1000, 1100, 1200, 1500)
BeckhoffTipps:Beckhoff verwendet zur Kommunikation hauptsächlich das ADS-Protokoll.
ADSEthernetCX-Reihe, TwinCAT2, TwinCAT3
InovanceTipps:Inovance verwendet hauptsächlich das MODBUS-Protokoll für die Kommunikation.
MODBUS TCPEthernetSerie AC, Serie AM, Serie H5U, Serie H3U
MODBUS RTUSerieller AnschlussSerie AC, Serie AM, Serie H5U, Serie H3U, Serie H1U
KeyenceTipps:Keyence verwendet für die Kommunikation hauptsächlich das KV-Protokoll.
MC-3EEthernetKV-8000 Serie, KV-7000 Serie, KV-5500 Serie, KV-5000 Serie
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A und andere Ethernet-Geräte
KVEthernet
KVSerieller AnschlussKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicTipps:Panasonic verwendet für die Kommunikation hauptsächlich das Mewtocol-Protokoll.
MC-3EEthernetFP7-Serie, FP0H-Serie, FP-XH-Serie
MewtocolEthernetFP7-Serie, FP0H-Serie, FP-XH-Serie
MewtocolSerieller AnschlussFP7-Serie, FP0H-Serie, FP-XH-Serie, FP-X0-Serie, FP0R-Serie
DeltaTipps:Delta verwendet für die Kommunikation hauptsächlich das MODBUS-Protokoll.
MODBUS TCPEthernetAH-Serie, AS-Serie, AX-3-Serie, DVP-Serie (integriertes Ethernet)
MODBUS RTUSerieller AnschlussAH-Serie, AS-Serie, AX-3-Serie, DVP-Serie
XinJETipps:XinJE verwendet hauptsächlich das MODBUS-Protokoll für die Kommunikation.
MODBUS TCPEthernetCCSD-Serie, XA-Serie, XS-Serie, XG-Serie, XL-Serie
MODBUS RTUSerieller AnschlussCCSD-Serie, XA-Serie, XS-Serie, XG-Serie, XL-Serie, XC-Serie, XD-Serie
MegMeetTipps:MegMeet verwendet hauptsächlich das MODBUS-Protokoll für die Kommunikation.
MODBUS TCPEthernetSerie MC5100, Serie MC280, Serie MC200, Serie MC100, Serie MC80
MODBUS RTUSerieller AnschlussSerie MC5100, Serie MC280, Serie MC200, Serie MC100, Serie MC80
YaskawaTipps:Yaskawa verwendet zur Kommunikation hauptsächlich das MEMOBUS-Protokoll (unterstützt S7).
MemobusEthernetGL120/130-Serie, GL60-Serie, MP3000-Serie, MP2300-Serie, Z1000-Serie
FatekTipps:Fatek verwendet für die Kommunikation hauptsächlich das Fatek-Protokoll.
FatekSerieller AnschlussFBs-Reihe
KräftigTipps:Vigor verwendet für die Kommunikation hauptsächlich das private Protokoll VS.
VSSerieller AnschlussVS-Serie
FujiTipps:Fuji verwendet für die Kommunikation hauptsächlich das SPH/SPB-Protokoll.
SPHEthernetSPH-Reihe
SPBSerieller AnschlussSPB-Reihe

4G-Bänder

*Sie können sich an den Kundendienst wenden, um das entsprechende Modul für den Austausch auszuwählen.
 
Modul-StilFrequenzbänder
EC800K-CNLTE FDD: B1/B3/B5/B8
LTE TDD: B34/B38/B39/B40/B41
EG800K-EULTE FDD: B1/B3/B5/B7/B8/B20/B28
EG800K-LALTE FDD: B2/B3/B4/B5/B7/B8/B28/B66

Herunterladen

Antrag auf Produktmuster