In this tutorial, we will focus on explaining how the EG8200 Mini-CNC Gateway interfaces with Siemens CNC systems. We hope this proves helpful to you.
Starting today, we embark on a new journey. IOTRouter will launch a series of tutorials on how EG series gateways interface with CNC equipment. This tutorial series will feature case studies on well-known CNC brands such as Siemens, Mitsubishi, and many others.
1. EG8200 Mini-CNC Gateway
Сайт EG8200Mini-CNC is an CNC Data Acquisition Gateway designed for CNC equipment with powerful data acquisition and remote monitoring capabilities. The equipment supports a variety of industrial protocols, such as Modbus, MQTT, etc., and can be compatible with multi-brand CNC equipment to help users achieve remote CNC machine tool management.
2. Siemens CNC
Siemens CNC is a series of numerical control systems developed by Siemens. Through CNC systems, machine tools can precisely execute operations such as cutting, drilling, milling, and turning according to pre-programmed instructions (G-code/ISO code).
Siemens CNC systems are widely used in automotive, aerospace, mechanical manufacturing, mold processing, and other industries, offering high precision, high efficiency, and high reliability.
3. How to Interface the EG8200Mini-CNC gateway with Siemens CNC
Compatible CNC: SINUMERIK 802/810/828/840
1. Подключение оборудования
The Siemens CNC protocol utilizes Ethernet communication. Therefore, only ensure the gateway’s LAN port IP and the CNC’s IP are within the same subnet (Note: In special cases, they may be on different subnets, requiring routing configuration—consult technical support for details). IP addresses are assigned as follows in this example:
|
EG8200Мини-шлюз ЧПУ |
Siemens CNC |
|
| IP-адрес | 10.227.150.30 | 10.227.150.95 |
2. CNC Communication Parameters
Provided by the CNC engineer.
The CNC network port parameters are:
IP: 10.227.150.95, Порт: 102
3. Настройки шлюза
3.1. Настройки подключения ЧПУ
Drag a Siemens node from the CNC panel on the left. Double-click to open the settings page and configure as follows based on the PLC parameters:
Адрес: 10.227.150.95
Порт: 102
Таймаут соединения: 5000
Интервал сердцебиения: 60000
Таймаут данных: 2000
Интервал данных: 1000 (Read Cycle)
Loop Wait: 1000 (Data Point Read Interval)

3.2. Data Point Settings
Check the required data:

3.3. Тестирование
Нажмите кнопку Развернуть и наблюдайте, как каждые несколько секунд печатается точка данных. Проверьте полученные точки данных, чтобы подтвердить успешную связь!
Справочную таблицу точек данных см:
Это карта содержимого Yueque. Нажмите на ссылку для просмотра: https://iotrouter.yuque.com/zn3vdn/eg8000/xr6s46z90pevgwag